Remote cooling systems with mesh-based heat exchangers for cryogenic applications

Abstract: In the refrigeration technologies available for the 2 W - 5 W cooling power range at 4.5 K, innovative designs for intermediate cooling options are proposed between the large-scale cryogenic plants and small-scale commercially available cryocoolers. This paper presents a number of remote cooling solutions, which use high-effectiveness mesh-based counterflow heat exchangers (CFHEX) to support the aforementioned refrigeration domain. Additionally, the cooling power is aimed to be provided in a remote, distribute… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…The CERN Cryolab is doing extensive research on effective mesh-based counter-flow heat exchangers, which we plan to use in the present cryostat in view of their encouraging performance. [46][47][48] The RF equipment at low temperature is placed into an instrumentation vacuum chamber and cooled by thermal contacts to a copper plate onto which the cooling pipe is brazed in a meander. This additional instrumentation vacuum chamber (IVC) acts as a second vacuum environment and facilitates the maintenance of the RF equipment to which the data acquisition system (DAQ) and vector network analyzer (VNA) are connected.…”
Section: Cryostat Designmentioning
confidence: 99%
“…The CERN Cryolab is doing extensive research on effective mesh-based counter-flow heat exchangers, which we plan to use in the present cryostat in view of their encouraging performance. [46][47][48] The RF equipment at low temperature is placed into an instrumentation vacuum chamber and cooled by thermal contacts to a copper plate onto which the cooling pipe is brazed in a meander. This additional instrumentation vacuum chamber (IVC) acts as a second vacuum environment and facilitates the maintenance of the RF equipment to which the data acquisition system (DAQ) and vector network analyzer (VNA) are connected.…”
Section: Cryostat Designmentioning
confidence: 99%
“…This is undoubtedly beneficial and becomes extremely relevant for applications where a large mass needs to be cooled, e.g. cooling of superconducting magnets and radio-frequency cavities in future large-scale installations, such as the Future Circular Collider [10,23]. Even if the cooling source in these installations is different, e.g.…”
Section: Cryogenic Systems In Accelerator Complex At Cernmentioning
confidence: 99%
“…The performance of the system at the two chosen operating points is summarised in Tab. 8.1 [103]. "Point 1" serves to demonstrate the system performance at the nominal CIF temperature, and "Point 2" demonstrates the lowest temperature that could be achieved under the stated circulation constraints.…”
Section: Performance Of the Remote Cooling Systemmentioning
confidence: 99%
See 2 more Smart Citations