Remote Monitoring With Appropriate Reaction to Alerts Was Associated With Improved Outcomes in Chronic Heart Failure

Abstract: Background: Impedance-based remote monitoring (RM) failed to reduce clinical events in the OptiLink heart failure (HF) trial. However, rates of alert-driven interventions triggered by intrathoracic fluid index threshold crossings (FTC) were low indicating physicians’ inappropriate reactions to alerts. Methods: We separated appropriate from inappropriate contacts to FTC transmissions in the OptiLink HF trial (Optimization of Heart Failure Management Usin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
31
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(32 citation statements)
references
References 13 publications
1
31
0
Order By: Relevance
“…This would probably prevent the failure in reducing clinical events that has been previously reported when telemedicine alerts were not handled appropriately. Indeed, in the Optimization of Heart Failure Management Using OptiVol™ Fluid Status Monitoring and CareLink™ (OptiLink HF trial), impedance‐based remote monitoring failed to reduce clinical events, 23 the failure being ascribed to the low rate of alert‐driven interventions. Another reason could be the low sensitivity of impedance‐based HF alerts 24 that may have resulted in not treating potentially actionable events, or the high rate of false‐positive detections and a consequent increase in hospital admissions.…”
Section: Discussionmentioning
confidence: 99%
“…This would probably prevent the failure in reducing clinical events that has been previously reported when telemedicine alerts were not handled appropriately. Indeed, in the Optimization of Heart Failure Management Using OptiVol™ Fluid Status Monitoring and CareLink™ (OptiLink HF trial), impedance‐based remote monitoring failed to reduce clinical events, 23 the failure being ascribed to the low rate of alert‐driven interventions. Another reason could be the low sensitivity of impedance‐based HF alerts 24 that may have resulted in not treating potentially actionable events, or the high rate of false‐positive detections and a consequent increase in hospital admissions.…”
Section: Discussionmentioning
confidence: 99%
“…[ 17 ] The extent of RM of CIEDs goes beyond monitoring the device parameters and providing information on patients’ condition. [ 18 20 ] RM in CIEDs utilizes unidirectional communication from the CIED recipients to their physicians, and the CIEDs can be monitored on a daily basis. Although remote medical intervention (bidirectional communication) is impossible with CIED RM, experiences show enhanced patient satisfaction.…”
Section: Discussionmentioning
confidence: 99%
“…In a recent post-hoc exploratory analysis, patients who had a fluid threshold crossing alert and had an appropriate medical contact had a 39% relative risk reduction of the primary endpoint. This study highlight the importance of linking telemonitoring with medical interventions [60]. CorVue TM algorithm (St. Jude Medical, St. Paul, MN, USA) detects the intrathoracic impedance providing 12 daily measurements and comparing to a reference.…”
Section: Cardiac Implantable Electronic Devicesmentioning