1991
DOI: 10.1109/68.68057
|View full text |Cite
|
Sign up to set email alerts
|

Remote sensing of methane gas by differential absorption measurement using a wavelength tunable DFB LD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

1995
1995
2006
2006

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 58 publications
(15 citation statements)
references
References 6 publications
0
15
0
Order By: Relevance
“…The processing method includes direct measurement of the signal magnitude from the bandpass filter while the laser wavelength is locked to a gas absorption line by use of a reference gas cell 9,12 and measurement of the variation in the signal amplitude when the laser wavelength is scanned across a gas absorption line. 7 In this section we examine the use of a wavelength-modulation spectroscopy technique in which the laser wavelength is modulated sinusoidally at a relatively higher frequency while the average wavelength is locked to or scanned across a gas absorption line.…”
Section: Wavelength-modulation Spectroscopy In the Frequency-modulatementioning
confidence: 99%
“…The processing method includes direct measurement of the signal magnitude from the bandpass filter while the laser wavelength is locked to a gas absorption line by use of a reference gas cell 9,12 and measurement of the variation in the signal amplitude when the laser wavelength is scanned across a gas absorption line. 7 In this section we examine the use of a wavelength-modulation spectroscopy technique in which the laser wavelength is modulated sinusoidally at a relatively higher frequency while the average wavelength is locked to or scanned across a gas absorption line.…”
Section: Wavelength-modulation Spectroscopy In the Frequency-modulatementioning
confidence: 99%
“…For fiber gas sensor applications, the value of f is usually of the order of a few tens of kilohertz. 2,3,5,7 When the modulated laser light is passing through a gas sample with an ͑amplitude͒ absorption coefficient ␣͑͒, the output light intensity may be written as…”
Section: Wavelength Modulation Spectroscopy Based On Current Modulatimentioning
confidence: 99%
“…Because the average wavelength of the laser is locked to the center of the gas line ͑i.e., L0 ϭ g ͒ by the use of a reference loop and feedback control, 2,3,5,7 I͑t͒ may be written as…”
Section: Wavelength Modulation Spectroscopy Based On Current Modulatimentioning
confidence: 99%
See 2 more Smart Citations