Abstract:The efficiency of iron electrode based electrocoagulation (EC) technique at laboratory scale to remove lead (Pb) from battery industrial effluent in Bangladesh is investigated. Different combinations of voltage (15, 30 and 45), effluent pH (1, 3, 5, 7 and 9) and electrolysis time (15, 30, 45 and 60 minutes) at the EC reactor was examined for searching the ideal operating conditions of maximum lead removal. Initial battery effluent pH of 3, electro coagulating at 30 V for 15 minutes would be the optimum conditi… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.