2023
DOI: 10.3390/pr11072146
|View full text |Cite
|
Sign up to set email alerts
|

Removal of Paracetamol and Cu2+ from Water by Using Porous Carbons Derived from Agrowastes

Regiane C. Ferreira,
Thiago Peixoto de Araújo,
Diogo Dias
et al.

Abstract: Dende and babassu coconuts are largely used in tropical countries, namely in Brazil, for the extraction of oils from kernels. The remaining biowastes are industrially processed to produce porous carbons (PCs). PCs derived from dende and babassu biowastes and produced at an industrial scale have been characterized by textural, chemical, and ecotoxicological parameters. A commercial activated carbon (CC) of mineral origin has been used as a benchmarking material. Although the CC sample presented a higher surface… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2025
2025

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(1 citation statement)
references
References 61 publications
0
1
0
Order By: Relevance
“…86−88 This could be that Ferreira and coworkers used a lower pH, mass of adsorbent, high sample volume, and longer contact time, suggesting lower pH (Table 7) gave more ionic interactions and higher sample volume, which allowed more room for interactions for a longer time. 86 On the other hand, some researchers used similar pH conditions but higher sample volume and longer reaction time, which allowed for room and longer interactions between analytes and adsorbents. 87,88 However, a lower capacity obtained by Hamoudi and colleagues suggests that increased mass of adsorbent and longer reaction time did not have much influence on the adsorption capacities.…”
Section: Transmission Electron Microscopymentioning
confidence: 99%
“…86−88 This could be that Ferreira and coworkers used a lower pH, mass of adsorbent, high sample volume, and longer contact time, suggesting lower pH (Table 7) gave more ionic interactions and higher sample volume, which allowed more room for interactions for a longer time. 86 On the other hand, some researchers used similar pH conditions but higher sample volume and longer reaction time, which allowed for room and longer interactions between analytes and adsorbents. 87,88 However, a lower capacity obtained by Hamoudi and colleagues suggests that increased mass of adsorbent and longer reaction time did not have much influence on the adsorption capacities.…”
Section: Transmission Electron Microscopymentioning
confidence: 99%