2023
DOI: 10.1177/11297298231197290
|View full text |Cite
|
Sign up to set email alerts
|

Removal of stuck tunnelled dialysis line requiring cardiopulmonary bypass and venous repair

Lubna Bakr,
Jason Ali

Abstract: Tunnelled central venous dialysis catheters can usually be removed easily. However, their removal can become rarely complicated requiring more invasive techniques. We report a case in which cardiopulmonary bypass and repair of great veins was required for safe removal. A 38-year-old female with end-stage renal failure and a 3-year-old Hickman line inserted into her right internal jugular vein was referred to our cardiac surgical unit following failed attempts of line removal by local vascular surgical team usi… Show more