2008
DOI: 10.1016/j.jse.2008.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Repair integrity and clinical outcome after arthroscopic rotator cuff repair using single-row anchor fixation: A prospective study of single-tendon and two-tendon tears

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
31
0
2

Year Published

2009
2009
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(33 citation statements)
references
References 35 publications
0
31
0
2
Order By: Relevance
“…Advanced patient age and 2 or more torn rotator cuff tendons correlate with RCR failure. 20,29 Failed RCR is associated with advanced muscle atrophy and fatty degeneration. 14 Double-row RCR is increasingly used to maximize rotator cuff footprint coverage, although the current literature does not support the clinical benefit of double-row RCR.…”
Section: Failure To Healmentioning
confidence: 99%
“…Advanced patient age and 2 or more torn rotator cuff tendons correlate with RCR failure. 20,29 Failed RCR is associated with advanced muscle atrophy and fatty degeneration. 14 Double-row RCR is increasingly used to maximize rotator cuff footprint coverage, although the current literature does not support the clinical benefit of double-row RCR.…”
Section: Failure To Healmentioning
confidence: 99%
“…After the double-row suture anchor repair was tested, the medial aspect of the repair was released, leaving the lateral single row intact for testing ( Figure 4). Although midfootprint 27 and medial single-row repairs 37,40 have been described, this laterally based repair configuration was used to maximize footprint coverage, 9,31 minimizing bias against this repair.…”
Section: Repair Techniquesmentioning
confidence: 99%
“…Recently, numerous studies have looked at the efficacy of these approaches. [1][2][3][7][8][9]12,13,[15][16][17][18]20,21 The majority of these studies indicate that with current suture anchor techniques, for single tendon supraspinatus tendon tears, similar results are obtained with either the mini-open repair or the allarthroscopic repair. 2,3,7,8,12,13,15,16,18,20,21 The mini-open surgical repair technique has the option of various repair methods from bone tunnels to implantable suture anchors, while the all-arthroscopic surgical technique requires the use of implantable suture anchor devices 14 for the rotator cuff repair.…”
mentioning
confidence: 95%