1995
DOI: 10.1109/tgrs.1995.8746014
|View full text |Cite
|
Sign up to set email alerts
|

Repeat-pass SAR interferometry over forested terrain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
81
0

Year Published

2001
2001
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 146 publications
(83 citation statements)
references
References 21 publications
2
81
0
Order By: Relevance
“…Coherence has been used in many studies for estimating biomass parameters (e.g. Wegmuller and Werner, 1995;Hagberg et al, 1995;Fransson et al, 2002) and has been found to be strongly correlated to biomass volumes of young plantation forests.…”
Section: Remote Sensing Techniquesmentioning
confidence: 99%
“…Coherence has been used in many studies for estimating biomass parameters (e.g. Wegmuller and Werner, 1995;Hagberg et al, 1995;Fransson et al, 2002) and has been found to be strongly correlated to biomass volumes of young plantation forests.…”
Section: Remote Sensing Techniquesmentioning
confidence: 99%
“…Papathanassiou and Cloude (2001) used the German Aerospace Center's (DLR) E-SAR with L-band and H and V polarization. With respect to reference sites of eight coniferous and five deciduous stands, the standard deviation between measured and estimated heights was approximately 2.5 m. Hagberg et al (1995) used the spaceborne ERS-1 Cband as part of repeat-pass. The accuracy of forest stand height was in the order of 5 m.…”
Section: Radar Mapping For Forestmentioning
confidence: 99%
“…Interferometric SAR data contain information on the threedimensional structural properties of a forest, thus increasing the range of parameters measurable with respect to the intensity of the SAR backscatter (cf. Askne et al, 1997;Floury et al, 1996;Hagberg et al, 1995;Papathanassiou & Cloude, 2001;Santoro et al, 2005;Treuhaft et al, 1996).…”
Section: Introductionmentioning
confidence: 99%
“…In boreal forests the amplitude of the ERS interferometric SAR complex coherence, or simply the coherence, has been shown to present high sensitivity to biophysical parameters (Askne et al, 1997;Askne & Smith, 1996;Hagberg et al, 1995). This suggested the development of methods, based on either regression or semi-empirical models, that allowed the estimation of biophysical parameters from coherence measurements Fransson et al, 2001;Koskinen et al, 2001;Pulliainen et al, 2003;Santoro et al, 1999Santoro et al, , 2002Smith et al, 1998;Wagner et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation