2019
DOI: 10.1016/j.acra.2018.10.021
|View full text |Cite
|
Sign up to set email alerts
|

Repeatability of Regional Lung Ventilation Quantification Using Fluorinated (19F) Gas Magnetic Resonance Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
51
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 17 publications
(52 citation statements)
references
References 37 publications
1
51
0
Order By: Relevance
“…Further work in other disease states could better inform the clinical utility of the dynamic 19 F approaches. Although we did not perform repeatability scans as a part of this study, others have shown that dynamic 19 F ventilation imaging, albeit with a different scanning protocol, has good repeatability in normal subjects and subjects with chronic obstructive pulmonary diseases 26 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Further work in other disease states could better inform the clinical utility of the dynamic 19 F approaches. Although we did not perform repeatability scans as a part of this study, others have shown that dynamic 19 F ventilation imaging, albeit with a different scanning protocol, has good repeatability in normal subjects and subjects with chronic obstructive pulmonary diseases 26 …”
Section: Discussionmentioning
confidence: 99%
“…Although we did not perform repeatability scans as a part of this study, others have shown that dynamic 19 F ventilation imaging, albeit with a different scanning protocol, has good repeatability in normal subjects and subjects with chronic obstructive pulmonary diseases. 26 Several technical factors impacted our data, including challenges related to co-registration of 19 F, 129 Xe, and 1 H images. Proton images of the thoracic cavity and gas ventilation images were obtained during separate maximal inhalation breath-holds, making it likely that the same inspiratory capacity might not be reached consistently.…”
mentioning
confidence: 99%
“…An ideal RF coil should have full lung coverage and good B 1 homogeneity, but the coil should also be as small as patient comfort allows in order to minimize the RF power requirements and maximize receive sensitivity. Both single channel 19,20 and phased array 19 F RF coils 26 have been described for human lung imaging. Single channel flexible vest transmit/ receive RF coils typically provide a good image quality, while maintaining patient comfort and compliance.…”
Section: Gas Propertiesmentioning
confidence: 99%
“…19,20 Other designs use a rigid elliptical birdcage transmit and a flexible receive array with up to 16 channels. 26 The rigid transmit coil should have a superior B 1 homogeneity, at the expense of requiring more RF power for the larger transmit element compared to the flexible vest. The use of a phased array receive coil allows for accelerated image acquisitions with parallel imaging reconstruction (ie, GRAPPA).…”
Section: Gas Propertiesmentioning
confidence: 99%
“…Assessment of regional lung ventilation using 19 F gas MRI has been successfully compared with other imaging methods [22][23][24] and has shown a good repeatability. 25 The main drawback of this technique is the lower SNR in comparison to hyperpolarized gas MRI. Because the first breath after gas administration is of most clinical relevance and most sensitive for detection of hypoventilated lung segments, 26 the low SNR especially after only one breath of gas is a major limiting factor for clinical translation of 19 F MRI.…”
Section: Introductionmentioning
confidence: 99%