2016
DOI: 10.1002/cnma.201600194
|View full text |Cite
|
Sign up to set email alerts
|

Replication of Polymer‐Based Peptide Microarrays by Multi‐Step Transfer

Abstract: Peptide microarrays serve as a high-throughput tool for the readout of protein-peptide interactions. We present a multi-step purification of high-complexity peptide microarrays by transfer to specialized surfaces. Only correctly synthesized peptides are transferred from the synthesis surface to various substrates where they can be immobilized by a variety of different anchor molecules. Here, we demonstrate the transfer to rigid streptavidin, epoxide, gold, and azide surfaces. The reported method reduces the co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Assembled Peptide Structure on Surface via Transfer (Structured Synthesis) : In contrast to the unstructured synthesis, the 10:90‐PEGMA‐co‐MMA surface was prestructured via cLIFT to generate an array pattern. Therefore, Fmoc‐Gly‐OPfp was transferred and then coupled to the surface in the oven.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Assembled Peptide Structure on Surface via Transfer (Structured Synthesis) : In contrast to the unstructured synthesis, the 10:90‐PEGMA‐co‐MMA surface was prestructured via cLIFT to generate an array pattern. Therefore, Fmoc‐Gly‐OPfp was transferred and then coupled to the surface in the oven.…”
Section: Methodsmentioning
confidence: 99%
“…For the transfer, a custom‐built machine was used which presses a surface, containing cleaved peptides, onto a second array surface. The reaction medium between the two surfaces allows the diffusion of the cleaved peptides, which couple to the second surface without loss of lateral resolution.…”
mentioning
confidence: 99%
“…However, direct application of the known label-free detection methods, such as surface plasmon resonance methods [4,5,6], reflectometric interference spectroscopy [7], or resonator-like microstructures [8], is not possible for the surfaces on which commercially available high-density peptide arrays are synthesized. The transfer of the peptide spots to the standard free-label detection surfaces from a synthesis surface seems to be a very complicated procedure due to the spreading of the peptides cleaved and their amino-acid-dependent diffusion and adsorption [9].…”
Section: Introductionmentioning
confidence: 99%