2018
DOI: 10.1007/s11419-018-0422-0
|View full text |Cite
|
Sign up to set email alerts
|

Reporting the novel synthetic cathinone 5-PPDI through its analytical characterization by mass spectrometry and nuclear magnetic resonance

Abstract: In this work, the identification and characterization of the novel synthetic cathinone 5-PPDI found in a suspect drug sample was performed. MethodsThe suspect sample was analyzed by gas chromatography-mass spectrometry (GC-MS), Fourier-transformed infrared spectroscopy (FTIR), ultra-high performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS) and nuclear magnetic resonance (NMR). ResultsThe fragmentation observed in GC-MS and the identification of functional groups by FTIR were not eno… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
19
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(20 citation statements)
references
References 22 publications
1
19
0
Order By: Relevance
“…propose an unsupported 'shift' of the carbonyl group to explain the equivalent ion at m/z 135 for 3,4-MDPV [27]. Similarly, Pozo et al, Fabregat-Safont et al, and Qian et al propose mechanisms that involve the loss of CO directly from the aliphatic chain during the fragmentation of synthetic cathinones without the use of isotopic labeling to support these conclusions [28][29][30]. Our work now supports these proposed losses of CO.…”
Section: Introductionsupporting
confidence: 77%
See 2 more Smart Citations
“…propose an unsupported 'shift' of the carbonyl group to explain the equivalent ion at m/z 135 for 3,4-MDPV [27]. Similarly, Pozo et al, Fabregat-Safont et al, and Qian et al propose mechanisms that involve the loss of CO directly from the aliphatic chain during the fragmentation of synthetic cathinones without the use of isotopic labeling to support these conclusions [28][29][30]. Our work now supports these proposed losses of CO.…”
Section: Introductionsupporting
confidence: 77%
“…The fragmentation behavior of α-pyrrolidinophenone synthetic cathinones has been reported throughout literature; however, rarely are the underlying fragmentation mechanisms that lead to the observed fragment ions discussed or understood [14,16,20,[26][27][28][29]. Instead, the mechanism(s) are either absent, vague, or improbable.…”
Section: B) A)mentioning
confidence: 99%
See 1 more Smart Citation
“…UHPLC coupled to mass spectrometry (MS) plays an essential role in cathinone analysis, using both high-resolution MS (HRMS) and low-resolution MS/MS. Thus, most studies about the identification of novel cathinones [31][32][33] and the elucidation of their metabolites [34][35][36] have utilized UHPLC-HRMS, taking profit of the full-spectrum acquisition and high mass accuracy provided by this technique. UHPLC-MS/MS is the preferred technique for the accurate and sensitive determination of a predetermined list of compounds, and has often been used for studying the pharmacokinetics and pharmacodynamics of cathinones 20,[37][38][39][40] .…”
Section: Introductionmentioning
confidence: 99%
“…Synthetic cathinones are, nowadays, the second largest group of new psychoactive substances (NPS) monitored by the EMCDDA, and the most frequently seized NPS in 2015 1 . In the last years, the characterization of novel synthetic cathinones has been an on-going topic for forensic laboratories, showing that modifications of the cathinone moieties are the most frequent option for the production of novel stimulants 29 . Nonetheless, the number of new synthetic cathinones reported every year is decreasing 1 , and the effects profile of the newest cathinone derivatives as reported by users have been unfavourable (especially when compared to older cathinone analogues) 10 .…”
Section: Introductionmentioning
confidence: 99%