2005
DOI: 10.1016/j.radonc.2004.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

12
39
1
2

Year Published

2007
2007
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 47 publications
(54 citation statements)
references
References 24 publications
12
39
1
2
Order By: Relevance
“…However, based on the imaging data from the kV on‐board imager, significant shifts were measured sometimes when the patients were set up using only the stereotactic immobilization mask and localization system. Previous studies ( 7 , 10 ) reported large shifts using the BrainLAB mask immobilization, and showed that combining dental mold or upper jaw support with the mask improved the accuracy of patient setup in agreement with this work. Other studies measured the shifts required using the Exac‐Track system for patients who were immobilized using the BrainLAB immobilization mask system ( 7 ) and reported large shifts to correct patient position.…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…However, based on the imaging data from the kV on‐board imager, significant shifts were measured sometimes when the patients were set up using only the stereotactic immobilization mask and localization system. Previous studies ( 7 , 10 ) reported large shifts using the BrainLAB mask immobilization, and showed that combining dental mold or upper jaw support with the mask improved the accuracy of patient setup in agreement with this work. Other studies measured the shifts required using the Exac‐Track system for patients who were immobilized using the BrainLAB immobilization mask system ( 7 ) and reported large shifts to correct patient position.…”
Section: Discussionsupporting
confidence: 88%
“…Even with more rigid immobilization systems such as the head ring, ( 9 ) dental molds, or upper jaw supporting system, ( 7 , 10 ) the setup accuracy may be compromised by uncontrolled offsets that result from ring slippage. An independent verification system of the patient setup is important where secondary shifts might be detected and corrected.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Patients are immobilized in Scotch-cast masks. Image guidance with online correction of setup errors in 6 DOF replaced treatment based on external stereotactic coordinates [1,3,18]. The degree of precision achievable with this IGRT technique is mainly limited by the potential of the fixation device to immobilize the patient during treatment.…”
Section: Discussionmentioning
confidence: 99%
“…Tab. 2, [1,5,17,28]). Overall, our results are in line with other reports on setup accuracy for stereotactic radiotherapy (.…”
Section: Discussionmentioning
confidence: 99%