2014
DOI: 10.1097/mbp.0000000000000038
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of aortic pulse wave velocity as assessed with the new Complior Analyse

Abstract: The data showed an excellent reproducibility of the Complior Analyse for the assessment of aortic PWV when used in ideal conditions and by experienced observers. The technical profile presented shows that this device meets the requirements of quality for its inclusion in integrated clinical follow-up programs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…All measurements were performed by a highly experienced operator, with high reproducibility scores, as previously published [31], and a noteworthy concordance between invasive arterial parameters and the Complior-based pulse wave analysis method, which also been previously documented [32].…”
Section: Endpointsmentioning
confidence: 66%
“…All measurements were performed by a highly experienced operator, with high reproducibility scores, as previously published [31], and a noteworthy concordance between invasive arterial parameters and the Complior-based pulse wave analysis method, which also been previously documented [32].…”
Section: Endpointsmentioning
confidence: 66%
“…In our laboratory, the reproducibility of PWV measurements is excellent and comparable to that in literature. 10 The intraclass correlation coefficient for intraobserver variability was 0.93 (Po0.001), and for interobserver variability was 0.92 (Po0.001) Annual change in PWV was calculated as the absolute difference between PWV at follow-up and baseline, divided by the number of years of follow-up time.…”
Section: Arterial Stiffness Measurementsmentioning
confidence: 99%
“…All measurements were performed by a highly experienced operator, with high reproducibility scores, as previously published [15] , and a noteworthy concordance between invasive arterial parameters and the Complior-based pulse wave analysis method, which also been previously documented [16] .…”
Section: Acute Effects Of Smoking On the Arterial Function Of Young Hmentioning
confidence: 66%
“…Aortic pulse wave velocity and carotid pulse wave analysis Carotid-femoral pulse wave analysis (PWV), a measure of aortic stiffness, and carotid pulse wave analysis (PWA), were assessed simultaneously with the Complior® Analyse device (Alam Medical, Saint-Quentin-Fallavier, France) according to a previously described technique [13,15,16] . The measurements were made with the subjects in supine position with the neck in a slight hyperextension, and slightly rotated to the left, after a resting period of 10 minutes.…”
Section: Acute Effects Of Smoking On the Arterial Function Of Young Hmentioning
confidence: 99%