2017
DOI: 10.1016/j.mvr.2017.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of flow mediated skin fluorescence to assess microvascular function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 15 publications
0
18
0
Order By: Relevance
“…As previously demonstrated, the inter-day reproducibility of the FMSF device is excellent [10]. In this study, an assessment was made of inter-observer agreement using the same device in the same subject under identical conditions.…”
Section: Discussionmentioning
confidence: 79%
See 1 more Smart Citation
“…As previously demonstrated, the inter-day reproducibility of the FMSF device is excellent [10]. In this study, an assessment was made of inter-observer agreement using the same device in the same subject under identical conditions.…”
Section: Discussionmentioning
confidence: 79%
“…Moreover, it was demonstrated that both ischemic and hyperemic response differentiated between healthy subjects and patients with CAD suggesting microvascular dysfunction in those patients [10]. Therefore, given its relatively low cost and ease of use, FMSF seems a promising tool for the assessment of microvascular endothelial function in CVDs.…”
Section: Introductionmentioning
confidence: 99%
“…Since maximum light penetration of 340 nm UVB in the skin is about 0.3 to 0.5 mm, results are determined by fluorescence of NADH within the epidermis [16]. e wavelength of emitted NADH fluorescence (FL) is 460 nm (blue light) [13].…”
Section: Methodsmentioning
confidence: 99%
“…One technique, named flow-mediated skin fluorescence (FMSF), is based on noninvasive, real-time, in vivo measurement of NADH fluorescence, emitted from the skin cells of a forearm in response to the blockage and release of blood flow [12]. A pilot study conducted in patients with coronary artery disease (CAD) demonstrated that FMSF offered feasible and reproducible measurement of NADH which was sensitive to acute changes in the skin blood flow and yielded results associated with established plasma endothelial markers [13].…”
Section: Introductionmentioning
confidence: 99%
“…However, some authors [36] suggest that the decrease in NADH fluorescence intensity during reperfusion not only shows the change in mitochondrial function, but also in microcirculatory and endothelial functions related to the efficiency of blood supply to the skin. Both the skin blood vessels' thermoregulatory [37][38][39] and endothelial [40] functions improved after training.…”
Section: Exercise Responsementioning
confidence: 99%