2019
DOI: 10.1002/nbm.4095
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of human cardiac phosphorus MRS (31P‐MRS) at 7 T

Abstract: Purpose We test the reproducibility of human cardiac phosphorus MRS ( 31 P‐MRS) at ultra‐high field strength (7 T) for the first time. The primary motivation of this work was to assess the reproducibility of a ‘rapid’ 6½ min 31 P three‐dimensional chemical shift imaging (3D‐CSI) sequence, which if sufficiently reproducible would allow the study of stress‐response processes. We compare this with an established 28 min protocol, designed to record… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
53
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 26 publications
(61 citation statements)
references
References 31 publications
7
53
1
Order By: Relevance
“…The reasonable length of the scan meant that Pi estimation was also straightforward during stress. Although SNR, primarily due to low concentrations and the heart’s unfavourable geometry, limited our ability to measure Pi in 100% of scans, we report a technique whose repeatability competes with the slower CSI approach to Pi estimation 32 and the computation of PCr/ATP both at 3T 48 and 7T 39 . The protocol is feasible for use in patients, which will be further investigated, and can be delivered during dobutamine infusion at 7T; indeed, our study is the first to deliver vasoactive stress during MR examinations at this field strength.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations
“…The reasonable length of the scan meant that Pi estimation was also straightforward during stress. Although SNR, primarily due to low concentrations and the heart’s unfavourable geometry, limited our ability to measure Pi in 100% of scans, we report a technique whose repeatability competes with the slower CSI approach to Pi estimation 32 and the computation of PCr/ATP both at 3T 48 and 7T 39 . The protocol is feasible for use in patients, which will be further investigated, and can be delivered during dobutamine infusion at 7T; indeed, our study is the first to deliver vasoactive stress during MR examinations at this field strength.…”
Section: Discussionmentioning
confidence: 95%
“…The nominal voxel size was 25 × 15 × 33 mm 3 . Excitation was with a shaped pulse centred at +300 Hz relative to PCr 39 . The CSI orientation was cardiac short axis in‐plane rotated so the phase‐encoding direction with the highest resolution was in the anteroposterior direction to minimize skeletal muscle contamination.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, for applications where large anatomical inter-subject variability is expected, flexible RF coils are favorable to account for this heterogeneity in anatomy. Due to the longer wavelength for 31 P it is still possible to use single loop coils for 7 T 31 P MRS on the torso, which is the RF coil of choice in most published studies [13,20,21]. More elaborate designs include a 2-element Tx/Rx overlap array [9] and combinations of a Tx volume coil with Rx arrays [22][23][24].…”
Section: Introductionmentioning
confidence: 99%