2019
DOI: 10.1016/j.mri.2018.11.010
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of inhomogeneous magnetization transfer (ihMT): A test-retest, multi-site study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
29
3

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(35 citation statements)
references
References 28 publications
3
29
3
Order By: Relevance
“…The ICC scores of inverse ihMTR were slightly superior to ihMTR. Our ICC values are lower than a repeatability study of a steady-state Cartesian ihMT study 51 . However, the values are not directly comparable as that study used a 2.4×2.4×3.2 mm voxel size compared to our 1.5 mm isotropic voxel size, with a similar overall scan time.…”
Section: Discussioncontrasting
confidence: 72%
See 1 more Smart Citation
“…The ICC scores of inverse ihMTR were slightly superior to ihMTR. Our ICC values are lower than a repeatability study of a steady-state Cartesian ihMT study 51 . However, the values are not directly comparable as that study used a 2.4×2.4×3.2 mm voxel size compared to our 1.5 mm isotropic voxel size, with a similar overall scan time.…”
Section: Discussioncontrasting
confidence: 72%
“…To minimise the number of resampling operations all transforms between the MNI space and the MT-weighted native space were concatenated before application. Ten bilateral white matter tract ROIs were selected 51 .…”
Section: Methodsmentioning
confidence: 99%
“…The definition for the steady-state used here, that is, one off-resonance MT RF pulse between successive acquisition modules and a recovery period (if present) less than the time between adjacent MT pulses, also holds for other instances of simultaneous dual-offset RF irradiation. 5,7,17 The ihMT acquisitions proposed by Mchinda et al within a steady-state sequence do not fit this definition, because they make use of multiple, closely spaced (< 1 ms) MT pulses of alternating frequency for the dual-frequency experiments. Although the sequence proposed by Malik et al constitutes a true steadystate with one readout per TR, 17 that implementation is relatively SAR-intensive, while not making use of the increased ihMT signal available through a low duty-cycle implementation.…”
Section: Discussionmentioning
confidence: 99%
“…sequence comparable (albeit with more readouts) to previous steady-state ihMT implementations, 5,7 as well as a recent one that makes use of multiband pulses to achieve simultaneous RF irradiation, on-resonance and off-resonance. 17 This was in contrast to the prepared, ihMTRAGE sequence in which multiple MT pulses were used within the preparation module before acquisition.…”
mentioning
confidence: 99%
“…Recent developments in quantitative MT (qMT) methods attempt to reduce these confounding influences by providing more tissue-specific indices. 52 Another promising technique is inhomogeneous magnetization transfer (ihMT) 53 which appears to be specific to CNS lipids, which enrich myelin. Myelin water imaging (MWI) is another MRI technique designed to detect myelin alterations.…”
Section: Advances In Understanding Disease Mechanismsmentioning
confidence: 99%