2004
DOI: 10.1021/ie030277i
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of the Hydrodynamic Performance and Measurements in a Liquid−Liquid Kühni Extraction ColumnRelevance to Theoretical Model Evaluation

Abstract: Liquid−liquid systems research increasingly concentrates on computer simulations. However, the possibility of adequately testing complex theoretical models against experiments is hindered by a lack of reliable reproducibility data for laboratory and pilot-plant measurements. This strongly limits meaningful evaluation of the increasingly complex process and equipment models/algorithms that are being developed. In this work, experimental data are obtained in a pilot-scale Kühni column, and model parameters and s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
9
0

Year Published

2006
2006
2014
2014

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 8 publications
1
9
0
Order By: Relevance
“…Other details of these models and corresponding algorithms are given elsewhere by Ribeiro et al This algorithm, further adapted by Regueiras and co-workers , to model an agitated column, by stagewise solution of the population-balance equations under dynamic conditions, was designed to compute the drop-size distribution and local dispersed-phase holdup profiles along the column. Its use yielded an encouraging qualitative agreement with the experimental results obtained in a pilot-plant Kühni column …”
Section: Introductionsupporting
confidence: 72%
See 3 more Smart Citations
“…Other details of these models and corresponding algorithms are given elsewhere by Ribeiro et al This algorithm, further adapted by Regueiras and co-workers , to model an agitated column, by stagewise solution of the population-balance equations under dynamic conditions, was designed to compute the drop-size distribution and local dispersed-phase holdup profiles along the column. Its use yielded an encouraging qualitative agreement with the experimental results obtained in a pilot-plant Kühni column …”
Section: Introductionsupporting
confidence: 72%
“…The experimental evidence presented and discussed in earlier works ,, by this team suggests that, even in agitated liquid−liquid extraction columns, like Kühni columns, interdrop coalescence cannot be neglected. The same applies to simple mixers …”
Section: Introductionmentioning
confidence: 80%
See 2 more Smart Citations
“…The DSD is of significant importance in extraction processes since it determines interfacial area (mass transfer) and drop rise velocities (residence time). As a result, extensive research on various apparatus like columns 1, mixer settlers 2, separators 3, and tank reactors 4 has been performed. Comparing breakage and coalescence phenomena, the coalescence is more complex due to two effects.…”
Section: Introductionmentioning
confidence: 99%