2018
DOI: 10.1142/s0218001419550024
|View full text |Cite
|
Sign up to set email alerts
|

Research on a Precision and Accuracy Estimation Method for Close-Range Photogrammetry

Abstract: Precision and accuracy estimation is an important index used to reflect the measurement performance and quality of a measurement system. To reveal the significance and connotations of the precision and accuracy estimation index of a close-range photogrammetry system, several common precision and accuracy estimation methods are proposed. They are explained from a theoretical perspective, and the mechanism of the internal coincidence precision estimation and the external coincidence accuracy estimation are deduc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 2 publications
0
2
0
Order By: Relevance
“…By analysing the binocular vision system to adaptively adjust the weight of the observation points at different distances, the positioning accuracy in the depth direction is significantly enhanced, and the reliability of the adaptive‐weighting least‐squares strategy is also demonstrated. Additionally, the internal accuracy is further calculated by covariance matrix and unit weight variance to evaluate the performance of BA (Ma et al., 2019; Triggs et al., 2000). The internal accuracy of unweighted BA with joint segments is 4.7 mm, and is improved to 4.0 mm using iterative reweighting.…”
Section: Resultsmentioning
confidence: 99%
“…By analysing the binocular vision system to adaptively adjust the weight of the observation points at different distances, the positioning accuracy in the depth direction is significantly enhanced, and the reliability of the adaptive‐weighting least‐squares strategy is also demonstrated. Additionally, the internal accuracy is further calculated by covariance matrix and unit weight variance to evaluate the performance of BA (Ma et al., 2019; Triggs et al., 2000). The internal accuracy of unweighted BA with joint segments is 4.7 mm, and is improved to 4.0 mm using iterative reweighting.…”
Section: Resultsmentioning
confidence: 99%
“…For the length measurement accuracy of the industrial photogrammetry system, a dualfrequency laser interferometer (with a length uncertainty of 0.1 µm + 0.1 µm m −1 ) can be used to mark the length with high precision. It can be employed as the true value of the length and compared with the length measured by the corresponding industrial photogrammetry system to evaluate the length measurement accuracy of the industrial photogrammetry system [20].…”
Section: External Coincidence Accuracy Testmentioning
confidence: 99%