2016 27th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV) 2016
DOI: 10.1109/deiv.2016.7748697
|View full text |Cite
|
Sign up to set email alerts
|

Research on controlled switching in reducing unloaded power transformer inrush current considering circuit breaker's prestrike characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…During the making process of the VCB, there is a threshold electric field strength that determined whether breakdown occurs or not [32]. When the electric field strength exceeds the threshold electric field strength between the contacts, the prestrike arc occurs and the gap between the contacts at that instant is called prestrike gap, which is independent of the initial gap of the VCB [33]. However, if there is an inrush current in the prestrike process that causes erosion on contacts or the prestrike gaps are larger than 2 mm, the initial gap of the single-break VCB and the double-break VCB must be kept the same in order to compare the characteristics of prestrike gaps.…”
Section: Negative Effects Of the Double-break Vacuum Circuit Breakermentioning
confidence: 99%
“…During the making process of the VCB, there is a threshold electric field strength that determined whether breakdown occurs or not [32]. When the electric field strength exceeds the threshold electric field strength between the contacts, the prestrike arc occurs and the gap between the contacts at that instant is called prestrike gap, which is independent of the initial gap of the VCB [33]. However, if there is an inrush current in the prestrike process that causes erosion on contacts or the prestrike gaps are larger than 2 mm, the initial gap of the single-break VCB and the double-break VCB must be kept the same in order to compare the characteristics of prestrike gaps.…”
Section: Negative Effects Of the Double-break Vacuum Circuit Breakermentioning
confidence: 99%
“…6 that at instants before crossing zero, a pre-closing or pre-strike voltage has been created because of the decrease in dielectric withstand of the gap between the contacts. In the beginning, for the sake of simplicity, it is assumed that the line trapped charge is zero [26]. In this paper, this issue has been generalised to a case in which the trapped charge exists in the line side.…”
Section: Pre-strike Voltagementioning
confidence: 99%
“…Many studies [6–10] present point on wave switching (PWS) without considering LTC. In one of the most impressive study, [6], a PWS strategy is proposed in which there exists an imprecision since the closing instant is determined only by LTC polarities.…”
Section: Introductionmentioning
confidence: 99%