Research on the Deposition Characteristics of Integrated Prefabricated Pumping Station

Abstract: Based on the discrete phase model (DPM) solid–liquid two-phase flow model and MATLAB image processing technology, an integrated prefabricated pumping station was taken as the research object to study deposition characteristics under different flow rates, different particle diameters, and different liquid levels. Considering the incomplete symmetry of the internal flow of the prefabricated pumping station, deposition characteristics of the prefabricated pumping station under single/double pumps were also analyz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The CFD numerical computation software, Fluent was used to calculate the internal flow field in the prefabricated pumping station and a multiple coordinate model was adopted. The setting of DPM in Fluent was the same as in [11]. The flow field in the impeller was set to a rotating coordinate system, and the rest was set to a static coordinate system.…”
Section: Calculation Methods For the Internal Flow Fieldmentioning
confidence: 99%
See 2 more Smart Citations
“…The CFD numerical computation software, Fluent was used to calculate the internal flow field in the prefabricated pumping station and a multiple coordinate model was adopted. The setting of DPM in Fluent was the same as in [11]. The flow field in the impeller was set to a rotating coordinate system, and the rest was set to a static coordinate system.…”
Section: Calculation Methods For the Internal Flow Fieldmentioning
confidence: 99%
“…The calculation domain of the whole flow field was divided with the ICEM code. In order to improve the accuracy of the calculation and computing efficiency, a grid independence check was performed [11].…”
Section: Grid Generationmentioning
confidence: 99%
See 1 more Smart Citation
“…Other researchers analyzed the stability of centrifugal pump from the perspective of energy change 1218 and vortex development. 1926 These studies give researchers a clear understanding of the internal flow characteristics of centrifugal pumps under quasi-steady conditions.…”
Section: Introductionmentioning
confidence: 99%
“…The relationship between tank bottom diameter and tank height was studied, and the basic mechanism of sediment deposition in prefabricated pumping stations was expounded. Based on the discrete solid-liquid two-phase flow model (DPM) and MATLAB image processing technology, Kang W.et al [14] analyzed the settlement characteristics of a prefabricated pumping station under the action of a single pump and double pumps and measured the movement track of sediment particles at the bottom of the pump station. Qing L.et al [15] revealed the flow characteristics of water and sediment in the prefabricated pumping station and optimized the geometric parameters of the water tank to reduce sand deposition.…”
Section: Introductionmentioning