2019
DOI: 10.1109/tasc.2019.2892519
|View full text |Cite
|
Sign up to set email alerts
|

Research on the Parameter Matching Between Active SI-SFCL and DC Circuit Breaker in DC systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…When the current begins to decay, I5 is smaller than that without CLP. As can be seen from (7) and (8), the reduction of I5 reduces the interruption time and energy dissipation of SA. Additionally, the ETP forms a loop with the inductors which results in the reduction of the interruption time and dissipated energy.…”
Section: Analysis Of Stage IIImentioning
confidence: 93%
See 1 more Smart Citation
“…When the current begins to decay, I5 is smaller than that without CLP. As can be seen from (7) and (8), the reduction of I5 reduces the interruption time and energy dissipation of SA. Additionally, the ETP forms a loop with the inductors which results in the reduction of the interruption time and dissipated energy.…”
Section: Analysis Of Stage IIImentioning
confidence: 93%
“…Compared to the DC fault ride-through scheme using MMCs with self-blocking sub-modules (SMs), the DC circuit breaker (DCCB) based protection can ensure the selectivity of clearing the DC fault and a fast system restoration [5]- [7]. Hence, DCCBs may have a broad prospect in HVDC grids.…”
mentioning
confidence: 99%
“…In [162], the Yttrium Barium Copper Oxygen-coated conductor tape as a resistive type of superconducting fault current limiter is determined as a good candidate for HVDC grid applications. In [163], a study on the parameter matching between active saturated Iron-core superconducting fault current limiter and DC CBs is conducted. In addition, the characteristics of DC CB using transformer-type superconducting fault current limiter for DC fault current interruption are analyzed in [164].…”
Section: Other Types Of DC Circuit Breakersmentioning
confidence: 99%
“…These modifications were dedicated to decreasing the over-voltage issue on the SC coil and protecting the dc source when a fault occurs. In addition, the parameters matching and constrains between the FCL and direct current circuit breaker (DCCB) were also carried out in [70], [71]. Both theoretical and simulated results show that the k of the FCL is over 1000 since the initial inductance is almost zero, while the react time t c is less than 1ms.…”
Section: Iron Core Inductive Type Fclmentioning
confidence: 99%