2022
DOI: 10.3389/fenrg.2021.835440
|View full text |Cite
|
Sign up to set email alerts
|

Research on the Unstable Branch Screening Method for Power System With High-Proportion Wind Power

Abstract: The sooner the system instability is predicted and the unstable branches are screened, the timelier emergency control can be implemented for a wind power system. In this paper, aiming at the problem that the existing unstable branch screening methods are lack prejudgment, an unstable branch screening method for power system with high-proportion wind power is proposed. Firstly, the equivalent external characteristics model of the wind farm was deduced. And based on this, the out-of-step oscillation characterist… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 28 publications
(28 reference statements)
0
1
0
Order By: Relevance
“…The dynamic characteristics of wind power units are significantly different from traditional synchronous generators, and the power system's rotor angle stability characteristics have been profoundly changed (Agarala et al, 2022;Yadav and Saravanan, 2022). On the one hand, the opening space of traditional synchronous machines is occupied, and the system equivalent inertia is reduced, the risk of power system transient instability under large disturbances and extreme faults is correspondingly increasing (Tang et al, 2020;Tang et al, 2022). On the other hand, the primary frequency regulation capability of wind power units and their support to the grid is insufficient (Zhang et al, 2022).…”
Section: Introductionmentioning
confidence: 99%
“…The dynamic characteristics of wind power units are significantly different from traditional synchronous generators, and the power system's rotor angle stability characteristics have been profoundly changed (Agarala et al, 2022;Yadav and Saravanan, 2022). On the one hand, the opening space of traditional synchronous machines is occupied, and the system equivalent inertia is reduced, the risk of power system transient instability under large disturbances and extreme faults is correspondingly increasing (Tang et al, 2020;Tang et al, 2022). On the other hand, the primary frequency regulation capability of wind power units and their support to the grid is insufficient (Zhang et al, 2022).…”
Section: Introductionmentioning
confidence: 99%