2017 4th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) 2017
DOI: 10.1109/icepe-st.2017.8188874
|View full text |Cite
|
Sign up to set email alerts
|

Researches on interruption characteristics of a hybrid HVDC circuit breaker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Energies 2019, 12, x 2 of 15 breaking and must be higher than the system voltage, so this method is only applicable to lower voltage levels [12,13]. The second method is to use the resonant current generated by the LC resonant commutating branch, superimposing it on the fast mechanical switch branch, causing its current to quickly cross zero and extinguish the arc, while transferring the current of the fast mechanical switching branch to the LC resonant commutation branch.…”
Section: Project Overviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Energies 2019, 12, x 2 of 15 breaking and must be higher than the system voltage, so this method is only applicable to lower voltage levels [12,13]. The second method is to use the resonant current generated by the LC resonant commutating branch, superimposing it on the fast mechanical switch branch, causing its current to quickly cross zero and extinguish the arc, while transferring the current of the fast mechanical switching branch to the LC resonant commutation branch.…”
Section: Project Overviewmentioning
confidence: 99%
“…The first method is to use the arc voltage generated by the mechanical switch during the breaking process to achieve current zero crossing. In order to reduce the arcing time and reduce the influence on the ablation of the contacts, it is required that the arc voltage must be established quickly in the initial stage of the breaking and must be higher than the system voltage, so this method is only applicable to lower voltage levels [12,13]. The second method is to use the resonant current generated by the LC resonant commutating branch, superimposing it on the fast mechanical switch branch, causing its current to quickly cross zero and extinguish the arc, while transferring the current of the fast mechanical switching branch to the LC resonant commutation branch.…”
Section: Introductionmentioning
confidence: 99%
“…The development of the DC power grid requires reliable DC breakers, Hybrid circuit breakers that use fast switching. It is currently the focus of DC switching technology applications [4][5] . The turnoff fault current time of the power electronic switch is very short, so the speed of the mechanical switch is an important parameter for the DC breaker [6] .…”
Section: Introductionmentioning
confidence: 99%