2020
DOI: 10.1109/tasc.2020.2975192
|View full text |Cite
|
Sign up to set email alerts
|

Residual Flux Measurement of the Single-Phase Transformer Based on Transient Current Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…Based on the magnetic circuit analysis [25], the relationship between the equivalent inductance Leq and μrd at Br is expressed as = 2 0 (5) where N expresses the ratio of measuring winding, S and l represent the cross-sectional area and the average magnetic path length of the iron core, respectively. μ0 expresses the vacuum permeability of air, and its value is 4π×10 -7 H/m.…”
Section: Determining Direction Of Residual Flux Densitymentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the magnetic circuit analysis [25], the relationship between the equivalent inductance Leq and μrd at Br is expressed as = 2 0 (5) where N expresses the ratio of measuring winding, S and l represent the cross-sectional area and the average magnetic path length of the iron core, respectively. μ0 expresses the vacuum permeability of air, and its value is 4π×10 -7 H/m.…”
Section: Determining Direction Of Residual Flux Densitymentioning
confidence: 99%
“…However, this method uses the magnetization curve in the simulation model, thus this accuracy is greatly reduced and the Br direction is not judged. To address the limitations of this approach, in [25], author analyzes the relationship between Br and transient current difference. However, the measurement time of transient current difference is not easily determined, which may result in a lower accuracy of calculated Br.…”
Section: Introductionmentioning
confidence: 99%
“…However, the existence of the tank of the actual transformer makes the fluxgate unable to get close to the iron core, and the small signal of the leakage flux is sensitive to any kind of possible noise. The remanence can also be obtained according to the empirical equation between the remanence and the measured small voltage and current signals, including amplitude of the transient current difference [12], extremum time of the transient current difference [13], time constant of the transient current [14] and the area of minor hysteresis loop [15]. The determination of the empirical equation requires a lot of experiments or simulations, which is difficult to conduct on such many types of transformers in the actual power system.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the results were verified by experiments. A method for interpreting the residual flux of a single-phase transformer by sequentially applying two Direct Current (DC) voltages of opposite polarity to the transformer windings and then detecting their corresponding transient response currents was proposed in [6]. The equation between the residual flux and the transient current difference was fitted using the data analysis method.…”
Section: Introductionmentioning
confidence: 99%