2020
DOI: 10.1007/s11340-019-00571-7
|View full text |Cite
|
Sign up to set email alerts
|

Residual Thermal Strain Distribution Measurement of Underfills in Flip Chip Electronic Packages by an Inverse Approach Based on the Sampling Moiré Method

Abstract: Residual deformation evaluation of underfill (UF) materials in flip chips is crucial to improve the reliability of electronic packages. In this study, we propose to evaluate the residual thermal strain distributions using an inverse method based on the sampling moiré technique. Even if a grid pattern is fabricated on the specimen at room temperature, the residual strain distributions at an arbitrary temperature relative to the specimen formation temperature can be successfully calculated. The residual strain d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 24 publications
0
9
0
Order By: Relevance
“…Generally, the cubic spline interpolation was implemented to generate the phase-shifting moiré fringes. [24] Furthermore, the moiré phase can be calculated from the phase-shifting method using a discrete Fourier transform (DFT) algorithm [31] :…”
Section: D Moiré Phase Analysis Using the Sm Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Generally, the cubic spline interpolation was implemented to generate the phase-shifting moiré fringes. [24] Furthermore, the moiré phase can be calculated from the phase-shifting method using a discrete Fourier transform (DFT) algorithm [31] :…”
Section: D Moiré Phase Analysis Using the Sm Methodsmentioning
confidence: 99%
“…In the SM method, the grating is downsampled with sampling pitch p s , and then moiré patterns are generated by cubic spline interpolation. [24] Taking a one-dimensional SM method as an example, owing to the lack of sufficient grayscale information near the specimen edges, overinterpolation will occur, which results in a large phase error (see Figure 5). Figure 5a indicates that because of equally spaced sampling, the interpolated values of the moiré patterns near the specimen edges exceeded the original range of the grey value.…”
Section: Correction Of the Strain Field Near The Specimen Edgesmentioning
confidence: 99%
See 2 more Smart Citations
“…The DIC method is simple but weak against noise because the deformation carrier is speckled, which is difficult to extract from random noise. In contrast, ESPI has high deformation sensitivity but requires strong anti-vibration measures [30] aside from the costs.…”
Section: Introductionmentioning
confidence: 99%