Abstract:The authors examined the relationship between patency after thrombectomy of clotted dialysis grafts and intraoperative measurements of flow (Q), pressure gradient (PGR), and longitudinal resistance (RL). Eighteen thrombosed arteriovenous (AV) grafts underwent 21 thrombectomies. Pressures at arterial (P1) and venous (P2) ends of the AV grafts were determined with 22-gauge catheters and standard transducers; flow was measured with transit-time probes; arithmetic averaging of waveforms was used to compute mean Q,… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.