Conference on Lasers and Electro-Optics 2017
DOI: 10.1364/cleo_si.2017.sw1l.7
|View full text |Cite
|
Sign up to set email alerts
|

Resolving gas temperature distributions with single-beam dual-comb absorption spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…Improvement in laser source and tomographic algorithms will contribute to greater accuracy in the temperature and concentration distribution reconstruction, using either of the two approaches above. Rieker et al have extended the single LOS technique from advanced and expensive diode lasers with much broader tuning range (up to 10-15 cm −1 ) to a dual-frequency comb spectrometer [66,67]. The temperature distribution reconstruction accuracies increase as more absorption lines are incorporated.…”
Section: Summary Of Measurement Schemesmentioning
confidence: 99%
“…Improvement in laser source and tomographic algorithms will contribute to greater accuracy in the temperature and concentration distribution reconstruction, using either of the two approaches above. Rieker et al have extended the single LOS technique from advanced and expensive diode lasers with much broader tuning range (up to 10-15 cm −1 ) to a dual-frequency comb spectrometer [66,67]. The temperature distribution reconstruction accuracies increase as more absorption lines are incorporated.…”
Section: Summary Of Measurement Schemesmentioning
confidence: 99%
“…8.17). A relatively large number of spectral transition lines can be accessed using widely tunable laser sources such as dual-comb spectrometer [27,43], external cavity lasers [25,44], multiplexed laser systems [45], MEMS-vertical cavity surface emitting laser (VCSEL) [46], and others. Apart from the number of spectral transitions being scanned, the database used for inferring the mole fraction/temperature also influences the measurement error significantly.…”
Section: Temperature Stratificationmentioning
confidence: 99%
“…Fig.8.17 Temperature profiles for different laser sources. Green line: Two-line technique with diode laser, blue line: 12 spectral lines with external cavity laser[44], and black line: dual-comb spectrometer covering 937 lines[43].…”
mentioning
confidence: 99%