1983
DOI: 10.1051/rphysap:0198300180103900
|View full text |Cite
|
Sign up to set email alerts
|

Resonance-enhanced coherent anti-Stokes Raman scattering in C2

Abstract: 2014 Des spectres de Diffusion Raman Anti-Stokes Cohérente (DRASC) à la résonance électronique ont été obtenus sur le radical C2 formé dans une décharge microonde et dans une flamme de chalumeau oxy-acétylénique. La résonance électronique a été obtenue en accordant les lasers dans le système de Swan. Des spectres d'émission de C2 sur la bande de Swan avaient au préalable été enregistrés par spectroscopie à transformée de Fourier et interprétés; ceci a permis de déterminer les conditions optimales d'enregistrem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

1985
1985
2016
2016

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(8 citation statements)
references
References 30 publications
1
7
0
Order By: Relevance
“…Attal et al [148] gave a detection limit of 10 10 molecules/cm 3 for C 2 and a similar number was found by Doerk et al [150] for CH radicals. At elevated pressure Attal et al calculated a detection sensitivity of 6 ppm for OH at atmospheric pressure and 60 ppm at 10 bar [144].…”
Section: Concentration Measurements and Thermometry Applicationssupporting
confidence: 72%
See 1 more Smart Citation
“…Attal et al [148] gave a detection limit of 10 10 molecules/cm 3 for C 2 and a similar number was found by Doerk et al [150] for CH radicals. At elevated pressure Attal et al calculated a detection sensitivity of 6 ppm for OH at atmospheric pressure and 60 ppm at 10 bar [144].…”
Section: Concentration Measurements and Thermometry Applicationssupporting
confidence: 72%
“…the diatomic species C 2 [147][148][149], CH [150], and NO [151,152]. Furthermore polyatomic molecules such as NO 2 [153], NH 2 [154], and C 2 H 2 [155] have been investigated using this technique.…”
Section: Electronic Enhancement Of Cars Allows Detection Of Minor Spementioning
confidence: 99%
“…C 2 concentrations are generally accepted to be between 10 12 and 10 14 cm Ϫ3 for the flame operating near stoichiometric conditions. 5,19 III. RESULTS Figure 2 shows a high resolution DFWM spectrum covering almost the entire ͑0,0͒ d 3 ⌸ g →a 3 ⌸ u Swan band of C 2 .…”
Section: A Optical Setupmentioning
confidence: 99%
“…Different methods based on laser spectroscopy resulted to be powerful tools to measure physical parameters in reacting gas flows even at high temperature (e.g. plasma, flames) 5,6 . The intrinsic non-intrusive nature of laser based diagnostic techniques allows to monitor the chemical reactions without altering the dynamic and thermodynamic properties of the medium under investigation.…”
Section: Introductionmentioning
confidence: 99%