2018
DOI: 10.11591/ijpeds.v9.i3.pp1445-1456
|View full text |Cite
|
Sign up to set email alerts
|

Resonance Propagation and Elimination in Integrated and Islanded Microgrids

Abstract: In this paper, a micro grid resonance propagation model is investigated. To actively mitigate the resonance using DG units, an enhanced DG unit control scheme that uses the concept of virtual impedance is proposed. It can be seen that a conventional voltage-controlled DG unit with an LC filter has a short-circuit feature at the chosen harmonic frequencies, whereas a current-controlled DG unit presents an open-circuit characteristic. The application of underground cables and shunt capacitor banks may introduce … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…b 3 (6) The voltage at PCC before islanding is V PCC and the load impedance is ZL. The load current is given by equation (7) V PCC I= L Z L (7) However, after islanding the voltage at PCC is changed to VPCC (1+ ΔV), now the change in current after islanding is given by…”
Section: Test System Under Study 31 Mathematical Modelling Of Proposmentioning
confidence: 99%
“…b 3 (6) The voltage at PCC before islanding is V PCC and the load impedance is ZL. The load current is given by equation (7) V PCC I= L Z L (7) However, after islanding the voltage at PCC is changed to VPCC (1+ ΔV), now the change in current after islanding is given by…”
Section: Test System Under Study 31 Mathematical Modelling Of Proposmentioning
confidence: 99%
“…In our project instead of quadratic programming we are using GA that helps in optimization of production cost and the power generated is smoother [14]- [15]. As the generated power is smooth the converters required are less and the sizes of passive elements that are used in the converters are also less when compared.…”
Section: Introductionmentioning
confidence: 99%
“…By observing these deviations the islanding is detected by active methods. The active methods are more efficient than passive methods, but they reduce the power quality [18][19] The low frequency current injected through the DQ controller of inverter based distributed generation presented will work inside the NDZ of a conventional frequency relay [20][21][22][23]. Large samples of data collected from non-islanding and islanding events such as voltage, current, power, P.f, etc.…”
Section: Introductionmentioning
confidence: 99%