2011
DOI: 10.1016/j.snb.2011.05.030
|View full text |Cite
|
Sign up to set email alerts
|

Resonant cantilever sensors operated in a high-Q in-plane mode for real-time bio/chemical detection in liquids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
39
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 64 publications
(39 citation statements)
references
References 21 publications
0
39
0
Order By: Relevance
“…Toxic metal ions. Pollution containing heavy metals, especially Hg 2+ , is a serious environmental problem [55][56][57] and the detection of its traces in wastewater is thus of substantial demand. [58][59] Compared with conventional detection methods, [60][61][62] such as colorimetric assay, cold-vapor atomic absorption spectrometry (AAS), and inductively coupled plasma spectroscopy (ICP), etc., QCM-based sensors are more desirable because they are portable enough for on-site monitoring of heavy metal ions in the real environment.…”
Section: Silica-based Mesoporous Materialsmentioning
confidence: 99%
“…Toxic metal ions. Pollution containing heavy metals, especially Hg 2+ , is a serious environmental problem [55][56][57] and the detection of its traces in wastewater is thus of substantial demand. [58][59] Compared with conventional detection methods, [60][61][62] such as colorimetric assay, cold-vapor atomic absorption spectrometry (AAS), and inductively coupled plasma spectroscopy (ICP), etc., QCM-based sensors are more desirable because they are portable enough for on-site monitoring of heavy metal ions in the real environment.…”
Section: Silica-based Mesoporous Materialsmentioning
confidence: 99%
“…Significant efforts have been made to improve their quality factor in liquid. Solutions include using larger cantilevers operated at high order resonant modes [5], using in-plane resonant modes [6], [7], implementing feedback loops [8], or incorporating a microchannel in the cantilever [9]. Using higher order or in-plane resonant modes is challenging because it is difficult to excite these modes due to the increased effective stiffness of the cantilever [10].…”
Section: Introductionmentioning
confidence: 99%
“…11 Therefore, other techniques have been developed to increase sensitivity. These include using a resonant frequency tracking circuit 12,13 using the higher order resonant modes of a millimeter-sized cantilever, [14][15][16][17][18][19][20] or integrating a suspended microchannel into a cantilever. 21,22 These techniques have provided sensitivities high enough for measuring a single bacterium.…”
Section: Introductionmentioning
confidence: 99%