2017
DOI: 10.1016/j.proeng.2017.10.725
|View full text |Cite
|
Sign up to set email alerts
|

Results of Modeling Operation of the High-Speed Regulator of Non-Contact Secondary Voltage of Furnace Transformer of the High-Power Arc Steel Furnace in Constant Primary Current Mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Using the relationship determined for power-voltage characteristics, and replacing the arc by the voltage source formula (28) and (29) at identical devices, we can present the coefficient K N in the following form: (30) and at different devices:…”
Section: Voltage Fluctuationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Using the relationship determined for power-voltage characteristics, and replacing the arc by the voltage source formula (28) and (29) at identical devices, we can present the coefficient K N in the following form: (30) and at different devices:…”
Section: Voltage Fluctuationsmentioning
confidence: 99%
“…In the research using computer measuring techniques, the following models can be distinguished: one based on a series connected resistor and inductance [10,11], the time-varying voltage source defined as a nonlinear function dependent on the length of the electric arc [12][13][14][15], and the classic based on nonlinear differential equations using Mayra equations and Cassie [16,17]. We should also mention the recently widely used simulation programs [18][19][20][21][22][23][24][25][26], including those based on neural networks [27][28][29][30].…”
Section: Introductionmentioning
confidence: 99%
“…The most important methods include dynamic [26][27][28], classic based on nonlinear differential equations [29], based on resistance and inductance [30], using a voltage source variable in time, and defined as a nonlinear function depending on the length of the electric arc [31][32][33]. For modeling arc devices, computer simulation programs are widely used [34][35][36][37][38][39][40][41][42].…”
Section: Modeling Of Voltage Fluctuations In the Operation Of A Singl...mentioning
confidence: 99%
“…The operational asymmetry is reduced by the use of the electrode position control system [20,21] and additional devices aimed at improving the energy quality [22][23][24][25]. It should also be mentioned that the arc furnaces is the source of fast voltage fluctuations [26][27][28][29][30][31].…”
Section: Introductionmentioning
confidence: 99%