2010
DOI: 10.1016/j.nima.2010.07.037
|View full text |Cite
|
Sign up to set email alerts
|

Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

Abstract: The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in 208 Tl and 214 Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 m 2 of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of dat… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
14
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(16 citation statements)
references
References 19 publications
2
14
0
Order By: Relevance
“…an electron from β decay of 212 Bi followed by a delayed α of 8.8 MeV from 212 Po with a typical half-life of 300 ns. A successful R&D has been conducted in 2006-2010 with two prototypes that have demonstrated the proof of principle of such a detector to reach very low backgrounds [3]. A bigger detector called BiPo-3 has been designed and built in 2012 in order to measure the final 82 Se foils for the SuperNEMO Demonstrator with a total sensitive area of 3.6 m 2 [4].…”
Section: Radiopurity Strategiesmentioning
confidence: 99%
“…an electron from β decay of 212 Bi followed by a delayed α of 8.8 MeV from 212 Po with a typical half-life of 300 ns. A successful R&D has been conducted in 2006-2010 with two prototypes that have demonstrated the proof of principle of such a detector to reach very low backgrounds [3]. A bigger detector called BiPo-3 has been designed and built in 2012 in order to measure the final 82 Se foils for the SuperNEMO Demonstrator with a total sensitive area of 3.6 m 2 [4].…”
Section: Radiopurity Strategiesmentioning
confidence: 99%
“…The detector consists of 2 face-to-face planar calorimeters made of pure aluminized polystyrene scintillators coupled to 5" low radioactivity PMTs to detect the b and a particles and measure the time delay to distinguish the 2 isotopes. A first prototype has proved the feasibility of this technique [23]. The final detector has been constructed in 2012 to measure the required level for 1.4 kg of SuperNEMO sources in 6 months.…”
Section: The Supernemo Experimentsmentioning
confidence: 99%
“…The "BiPo" detector has been developed by exploiting the beta and delayed alpha decays occuring in the natural radioactive chains of 208 Tl and 214 Bi. The target sensitivity of 10µBq/kg has been reached with the BiPo1 prototype [9].…”
Section: Supernemo Design Studymentioning
confidence: 99%