2016
DOI: 10.5604/15093492.1220823
|View full text |Cite
|
Sign up to set email alerts
|

Results of Total Cementless Hip Joint Arthroplasty with Taperloc Stem

Abstract: STRESZCZENIEWstęp. Ce lem pra cy jest przed sta wie nie wy ni ków za bie gów alo pla styk sta wu bio dro we go z za sto so wa niem trzpie nia Ta per loc.Ma te riał i me to dy. Do ba dań za kwa li fi ko wa no 117 pa cjen tów (75 ko biet i 42 męż czyzn), u któ rych wy kona no 121 za bie gów alo pla sty ki sta wu bio dro we go z uży ciem trzpie nia Ta per loc. Śred ni wiek pa cjen tów w dniu za bie gu wy no sił 53,8 lat (za kres od 24 do 75 lat). Śred ni okres ob ser wa cji wy no sił 159,5 mie się cy.Wy ni ki. W … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 11 publications
1
3
0
1
Order By: Relevance
“…On the other hand, McLaughlin and Lee [ 18 ] reported a higher revision rate of 9% (for any cause) when the follow-up period was extended to 20 years. Still, when revision rates due to aseptic loosening are analyzed, our rates are similar to others [ 9 , 10 , 19 21 ], as this was the reason for only a single surgery (1.3%). Regarding the non-stem components, survival was lower at 63.2% with liner wear being the major cause for failure and revision.…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…On the other hand, McLaughlin and Lee [ 18 ] reported a higher revision rate of 9% (for any cause) when the follow-up period was extended to 20 years. Still, when revision rates due to aseptic loosening are analyzed, our rates are similar to others [ 9 , 10 , 19 21 ], as this was the reason for only a single surgery (1.3%). Regarding the non-stem components, survival was lower at 63.2% with liner wear being the major cause for failure and revision.…”
Section: Discussionsupporting
confidence: 88%
“…The cemented implant, which is non-collared, is made of cobalt chrome and is polished. It has a tapered shape for optimal stability and utilizes the same conventional broaching system as the cementless implant [ 8 , 9 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The hip joint is particularly exposed to the effects of adverse muscle forces, increased spasticity, including, among others, the adductor muscles and the iliac-lumbar muscle [4]. Oblique pelvis significantly increases the risk of hip joint dislocation [2,4,5]. As a result, the hip joint pivot point is changed – from the femoral head center to the trochanter minor – the shape of the acetabulum is changed and the cervical-shaft angle is increased [6].…”
mentioning
confidence: 99%
“…Les prothèses totales de hanche (PTH) sans ciment avec tige conventionnelle ont d'excellents résultats avec un taux de survie à 10 ans qui dépasse 95% [1][2][3][4][5][6]. Depuis une dizaine d'année, avec le développement des techniques mini-invasives, de multiples PTH à tige courte ont fait leur apparition avec comme objectifs de s'adapter à des voies d'abord plus courtes, de préserver le stock osseux trochantérien, de permettre une répartition des charges plus physiologiques au niveau de l'extrémité proximale du fémur afin de réduire le stress shielding, et enfin de faciliter les reprises chirurgicales [7,8].…”
Section: Introductionunclassified