2005
DOI: 10.1016/j.jcrs.2004.06.089
|View full text |Cite
|
Sign up to set email alerts
|

Retained ophthalmic viscosurgical device material in the capsular bag 6 months after phacoemulsification

Abstract: We present a 63-year-old man who developed low-grade endophthalmitis 6 months after phacoemulsification and implantation of a foldable posterior chamber intraocular lens (IOL). The capsular bag was distended, but shallowing of the anterior chamber was not observed. Chemical analysis of the clear fluid aspirated from the capsular bag behind the IOL revealed the presence of an ophthalmic viscosurgical device.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…35 Other studies have additionally shown that residual OVDs lodged in the trabecular mesh can prevent the outflow of aqueous fluid, thereby causing elevated IOP in the first 24 h after surgery. 36 Certainly, the retained OVD is not the only reason that increases IOP in the first postoperative day. The unappropriate wound closure, insufficient cortex cleaning, trauma to the iris and anterior chamber inflammation are well known other risk factors.…”
Section: Discussionmentioning
confidence: 99%
“…35 Other studies have additionally shown that residual OVDs lodged in the trabecular mesh can prevent the outflow of aqueous fluid, thereby causing elevated IOP in the first 24 h after surgery. 36 Certainly, the retained OVD is not the only reason that increases IOP in the first postoperative day. The unappropriate wound closure, insufficient cortex cleaning, trauma to the iris and anterior chamber inflammation are well known other risk factors.…”
Section: Discussionmentioning
confidence: 99%
“…However, there are studies which describe problems related with viscoelastic substance. The IOP elevation by viscoelastic substances is caused by a reduction of aqueous outflow due to blockage of the trabecular meshwork where the fluids exit the eye, which was first published in 1990 [18] and later confirmed by other authors in vivo and in vitro [10,22,23]. Therefore, complete removal of viscoelastic substance is recommended after IOL implantation.…”
Section: Viscoelastic Substance: Advantages and Problemsmentioning
confidence: 95%
“…Flare or Tyndall effect could be postoperatively detected after cataract surgery, which in part is frequent, but in excess that could be the manifestation of "toxic anterior segment syndrome" (TASS) after cataract surgery, and viscoelastic substance could be associated with this [23,24]. Also, an extra surgery time is necessary to introduce viscoelastic substance and to completely remove them from the anterior chamber, trying to avoid the problems previously described.…”
Section: Viscoelastic Substance: Advantages and Problemsmentioning
confidence: 99%
“… 13 However, there were also some problems, such as the postoperative rise of intraocular pressure (IOP) due to inadequate VS removal. 14 15 Anterior chamber reaction and inflammation associated with VS were also described as an anterior toxic segment syndrome. 16 17 …”
Section: Introductionmentioning
confidence: 99%