2016
DOI: 10.1007/s10967-016-4818-1
|View full text |Cite
|
Sign up to set email alerts
|

Retention profile and chromatographic separation of Y3+ from Sr2+ by Chelex-100 (cation ion exchanger) physically immobilized with ammonium ion

Abstract: Y 3? retention from aqueous media onto Chelex-100 sorbent impregnated with ammonium nitrate was studied. Y 3? uptake was rapid, reached maximum within 40 min and followed pseudo first order equation. Modified Chelex100 sorbent was successfully packed in column for separation of 90 Y from its parent 90 Sr. The method was based upon retention of Y 3? at pH 1.0 onto sorbent packed column in aqueous diethylenetriaminepentaacetic acid (DTPA). Y 3? species were recovered with HNO 3 and analyzed. The radiochemical an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 34 publications
0
8
0
Order By: Relevance
“…Thus, the rate-controlling step for Y 3+ sorption by the sorbent is not only gel diffusion control as in the ion exchangers [ 49 , 50 ]. At the initial stage of shaking time, the plot of % E of Y 3+ versus log time was fast and linear approving the occurrence of intraparticle diffusion [ 10 , 50 ]. Thus, a 60 min shaking time was adopted in the following study.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Thus, the rate-controlling step for Y 3+ sorption by the sorbent is not only gel diffusion control as in the ion exchangers [ 49 , 50 ]. At the initial stage of shaking time, the plot of % E of Y 3+ versus log time was fast and linear approving the occurrence of intraparticle diffusion [ 10 , 50 ]. Thus, a 60 min shaking time was adopted in the following study.…”
Section: Resultsmentioning
confidence: 99%
“…A Geiger–Muller ( β − Counter) and window detector and a Scaler Ratementer SR7 ( γ -Scintillation Counter) were used for ordinary gamma ray counter and it is fixed with well NaI (Tl) crystal. A high purity germanium (HPGe) coupled to a calibrated multichannel gamma analyzer (Silena, Milan, Italy) was employed to test impurities in the irradiated Y 2 O 3 and SrCO 3 as reported earlier [ 10 ]. The activity of 90 Sr activity was monitored as reported [ 10 ].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations