SUMMARY TRIAL/RESTORATIVE DENTISTRY 3A| 2C| 2B| 2A| 1B| 1A| Chamfer or shoulder preparation can be used for metalfree polymer crowns on anterior and posterior teeth Do the location of and design used when preparing metal-free polymer crowns influence their survival and complication rate? Design This was a randomised controlled trial conducted in Germany. Intervention Subjects were randomly allocated to two crown-preparation designs, a chamfer or shoulder finishing line. The minimum occlusal and axial reduction was 1 mm and 0.5 mm, respectively. Build-ups were made with a composite material, using the corresponding dentine adhesive. After making impressions with polyether material, polymer crowns were manufactured on stone dies and adhesively luted with resin cement.Outcome measure Follow-up appointments were scheduled after 1 month, 1 year, 2 years and 3 years. Outcome measures included failures and other complications. The aesthetic and functional performance was evaluated subjectively by visual rating scales (VAS), from 0 (completely inadequate) to 10 (perfect).Results Seventy-one patients had a total of 114 (68 posterior and 46 anterior) single crowns prepared. The dropout rate was less than 5% per year, giving a sample of 100 crowns for the 3-year follow-up. During the 3-year observation period, 10 complications occurred, including three total fractures, three partial fractures and three decementations. Only four crowns (three total fractures and one partial fracture) had to be replaced, whereas two partial fractures could be repaired and all loosened crowns could be recemented. A Kaplan-Meier survival curve based on total failures indicated a probability of survival of 96% after 3 years. It revealed no significant effect of the location or the design used in crown preparation on the complication rate, however. Aesthetic and functional evaluation by the patients revealed a high acceptance of single polymer crowns, indicated by medians of 9-10 on the VAS. Conclusions From this 3-year observation period, it can be concluded that 0.5 mm chamfer and shoulder preparation ensure that the stability of metal-free polymer crowns for anterior and posterior teeth is acceptable. Long-term stability and wear remain to be evaluated, however.
CommentaryThe longevity of indirect restorations is an important issue but there is a shortage of data that can be applied clinically by the dental practitioner, particularly about the relative efficacy of different techniques. This prospective study sought to determine the effect of the finishing line and crown location, ie, anterior or posterior, on the performance of metal-free polymer crowns (Artglass, Heraeus Kulzer, Wehrheim, Germany). These have the benefit of requiring less axial tooth reduction than all ceramic or metal-ceramic crowns. A total of 71 patients were recruited, receiving a total of 114 crowns. Details of the inclusion criteria and other clinical findings were sparse. The finishing line for the crowns was either a chamfer or shoulder of 0.5 mm, with the prepar...