“…However, previous studies suggested that the incidence of wound and graft infection was lower with saphenous vein grafts. 12,13 Because of the lower infection rate and greater caliber compatibility with the vessels in the lower limbs, we routinely use saphenous vein grafts as the first option in our vascular reconstructions, and they were used in approximately 80% of patients requiring arterial or venous revascularization. In our series, graft occlusion occurred more frequently in patients who underwent vascular reconstruction with use of synthetic grafts, consistent with the results of prior studies.…”