Revealing Pt-seed-induced structural effects to tribological/electrical/thermoelectric modulations in two-dimensional PtSe2 using scanning probe microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 53 publications
1
10
0
Order By: Relevance
“…This suggests that not only the topographical effect but also structural effects can affect the friction of 2D materials at the nanoscale. The frictional properties of the PtSe 2 films were only recently investigated for the first time [27]. However, a comprehensive investigation focusing on the impact of structural properties on the tribological behaviour of PtSe 2 layers has not been carried out.…”
Section: Introductionmentioning
confidence: 99%
“…This suggests that not only the topographical effect but also structural effects can affect the friction of 2D materials at the nanoscale. The frictional properties of the PtSe 2 films were only recently investigated for the first time [27]. However, a comprehensive investigation focusing on the impact of structural properties on the tribological behaviour of PtSe 2 layers has not been carried out.…”
Section: Introductionmentioning
confidence: 99%
“…In the setup, the conductive probe connects to an ultra-low noise current preamplifier, like a typical current SPM. [14] Figure S5a (Supporting Information) shows a representative current signal on PDMS, simultaneously measured with the tip's vertical motion. In Figure S5b (Supporting Information), average current (I AVG ) was calculated by averaging the current signals acquired during a single tapping cycle.…”
Section: Resultsmentioning
confidence: 99%
“…For each tip, the elastic constant was precisely calibrated using the thermal tune method. [14] For KPFM study, after completing each topography line in the non-contact SPM mode using an electrically conducting tip, the feedback loop controlling the vertical piezo was turned off. Subsequently, the tip was lifted from the surface and traced over the pre-acquired topography at a constant distance (30 nm in this study).…”
Section: Methodsmentioning
confidence: 99%
“…30 Although the above advances have been made in PtSe 2 -based gas sensors, there is still more room to improve in terms of response sensitivity, limit of detection, recovery time, and hybrid platform integration. In addition, the transition from horizontal to vertical lattice orientation occurs in TAC process suggests various gas adsorption characteristics at different thickness morphologies, 31,32 which also has not been well investigated.…”
Section: Introductionmentioning
confidence: 99%