2006
DOI: 10.1039/b503857j
|View full text |Cite
|
Sign up to set email alerts
|

Reversed phase ion-pairing HPLC-ICP-MS for analysis of organophosphorus chemical warfare agent degradation products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0
1

Year Published

2007
2007
2016
2016

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(19 citation statements)
references
References 21 publications
0
18
0
1
Order By: Relevance
“…The sensitivity of bromine detection is additionally limited by the fact that spectral interferences from Ar (e.g. ArK, Ar 2 H) or adjacent Kr isotopes ( 80 Kr, 81 Kr) might contribute significantly to the background signal of the two available isotopes 79 Br and 81 Br (both exhibit an isotopic abundance of approximately 50%).…”
Section: Iodine and Brominementioning
confidence: 99%
See 2 more Smart Citations
“…The sensitivity of bromine detection is additionally limited by the fact that spectral interferences from Ar (e.g. ArK, Ar 2 H) or adjacent Kr isotopes ( 80 Kr, 81 Kr) might contribute significantly to the background signal of the two available isotopes 79 Br and 81 Br (both exhibit an isotopic abundance of approximately 50%).…”
Section: Iodine and Brominementioning
confidence: 99%
“…EMPA, IMPA, MPA IP-RP-HPLC-ICP-MS 0.14-0.27 g L −1 (as compounds) Extracts from spiked soil; water samples [81] Iodate sediment and water would remain elevated for still a long time. Generally, sample preparation was and still is a major issue in this topic [19].…”
Section: Tablementioning
confidence: 99%
See 1 more Smart Citation
“…Zum hochempfindlichen Nachweis dieser Hydrolyseprodukte in Umweltmedien wurde kürzlich eine IPC-Methode vorgestellt, die einen langkettigen Ionenpaarbildner (Myristylammoniumbromid) zur Trennung an einer Alltech Alltima RP-C 18 -Phase einsetzt. Die ICP-MS-Nachweisgrenzen bewegen sich im Bereich von 0,14-0,26 µg·L -1 (Richardson et al 2006).…”
Section: Phosphonsäuren Phosphonsäurealkylester Und Organophosphateunclassified
“…Richardson and Caruso published two papers dealing with the analysis of organophosphorus nerve agent degradation products, using either reversed-phase ion pairing HPLC 135 or GC 136 after trimethylsilyl (TMS) and tert-butyldimethylsilyl (TBDMS) derivatization for their separation. Phosphorus-specific detection during HPLC experiments has been carried out using collision cell ICP-MS and helium as the cell gas.…”
Section: Trends In Applying Icp-ms For Quantitative Analysismentioning
confidence: 99%