2002
DOI: 10.1016/s0165-022x(02)00140-9
|View full text |Cite
|
Sign up to set email alerts
|

Reversed-phase liquid chromatography of lisinopril conformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
10
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 29 publications
5
10
0
Order By: Relevance
“…Careful monitoring of all parameters is required. Our experiments using the recommended column and eluant showed that alteration of pH by 0.2 units, a 2 -3% decrease in the acetonitrile concentration, and a decrease in temperature by a few degrees could lead to broadening of the lisinopril peak, sometimes with splitting, pointing to the existence of multiple forms of lisinopril in solution, consistent with data reported in [3,10].…”
Section: Resultssupporting
confidence: 91%
“…Careful monitoring of all parameters is required. Our experiments using the recommended column and eluant showed that alteration of pH by 0.2 units, a 2 -3% decrease in the acetonitrile concentration, and a decrease in temperature by a few degrees could lead to broadening of the lisinopril peak, sometimes with splitting, pointing to the existence of multiple forms of lisinopril in solution, consistent with data reported in [3,10].…”
Section: Resultssupporting
confidence: 91%
“…The result obtained is the normal behavior for most compounds in the reversed phase mode, i. e. decreasing retention with increasing temperature. The same behavior was noted in a previous study using a column fabricated by a standard organosilanization protocol [15]. Therefore, as demonstrated in an earlier study of hydride type phases, they perform under most reversed-phase conditions like typical commercial C18 materials [16].…”
Section: Reversed Phasesupporting
confidence: 82%
“…Linsinopril and its analogs have been analyzed by reversed-phase liquid chromatography [15]. Therefore some of its chromatographic behavior is reasonably wellknown on conventional C18 stationary phases.…”
Section: Reversed Phasementioning
confidence: 99%
“…As a result, the goal was to obtain a symmetrical chromatographic peak of lisinopril, using a mobile phase with pH 7-7.5 without using ion pair reagents and column heating, even though previous studies [29,30] demonstrated that these factors cause isomerization, i.e. rotamerization of lisinopril leading to splitting and/or tailing of the obtained chromatographic peak.…”
Section: Methods Development and Optimizationmentioning
confidence: 99%