2014
DOI: 10.1007/s00402-014-2135-0
|View full text |Cite
|
Sign up to set email alerts
|

Reversed shoulder arthroplasty with inversed bearing materials: 2-year clinical and radiographic results in 101 patients

Abstract: IntroductionThis study documents 2-year clinical and radiographic results following reversed total shoulder arthroplasty using a novel prosthesis with inverted bearing materials (polyethylene glenoid; metal humeral component). This design was intended to avoid massive PE abrasion on the humeral side. Therefore, we predicted a lack of subsequent osteolysis-induced exacerbation of scapular notching, and because of other design features and modified operating technique a reduced notching rate.Materials and method… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
3
2

Relationship

3
7

Authors

Journals

citations
Cited by 38 publications
(11 citation statements)
references
References 32 publications
0
11
0
Order By: Relevance
“…Both materials show similar wear, so they are equally valid options [5355]. A polyethylene glenosphere combined with a metal humeral inlay has the advantage that it creates less polyethylene debris when scapular notching would occur.…”
Section: Glenosphere Optionsmentioning
confidence: 99%
“…Both materials show similar wear, so they are equally valid options [5355]. A polyethylene glenosphere combined with a metal humeral inlay has the advantage that it creates less polyethylene debris when scapular notching would occur.…”
Section: Glenosphere Optionsmentioning
confidence: 99%
“…The primary aim of this study was to measure the TE's for RSA 6,12, [20] who agreed to the informed consent approved by the local ethical committee. Excluded were the patients with trauma/fracture, secondary osteoarthritis, no informed consent, with rheumatoid arthritis, neoplasia, with incomplete data and who had a revision (change of basic parts of the implants) in the first two years.…”
Section: Introductionmentioning
confidence: 99%
“…The type of prosthesis used in this study (A nis® inverse, Fa Mathys, Bettlach, Switzerland) was developed and introduced to the market in 2007. It has been clinically and radiographically tested [12] and can be followed in the implant registries of the Netherlands, UK, AUS and NZ. The outcomes of RSA is promising and the good mid-term results are documented in different studies [6,7,[13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%