2021
DOI: 10.3390/app112311137
|View full text |Cite
|
Sign up to set email alerts
|

Review of Chloride Ion Detection Technology in Water

Abstract: The chloride ion (Cl−) is a type of anion which is commonly found in the environment and has important physiological functions and industrial uses. However, a high content of Cl− in water will do harm to the ecological environment, human health and industrial production. It is of great significance to strictly monitor the Cl− content in water. Following the recent development of society and industry, large amounts of domestic sewage and industrial sewage are discharged into the environment, which results in th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 53 publications
0
5
0
Order By: Relevance
“…The effects of anions on the chemical stability of ceMoS 2 were probed in the presence of 1–20 mM NaCl, considering that Cl – is one of the most common anions in both natural water 43 and wastewater. 44 Given the correlation between the absorbance at 450 nm and the concentration of suspended MoS 2 ( Figure S2 ), the changes in the concentration of MoS 2 nanosheets were tracked with the normalized absorbance A t / A 0 , where A t and A 0 are the 450 nm absorbance of the ceMoS 2 dispersion at time t and the initial point, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The effects of anions on the chemical stability of ceMoS 2 were probed in the presence of 1–20 mM NaCl, considering that Cl – is one of the most common anions in both natural water 43 and wastewater. 44 Given the correlation between the absorbance at 450 nm and the concentration of suspended MoS 2 ( Figure S2 ), the changes in the concentration of MoS 2 nanosheets were tracked with the normalized absorbance A t / A 0 , where A t and A 0 are the 450 nm absorbance of the ceMoS 2 dispersion at time t and the initial point, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The same survey tools were used in all years of the study. The measurements made with the multiparametric probe are subject to error due to the specifics of the tool, so the actual values of the parameters (especially those measured with ion-selective sensors) may differ from the real values measured with other methods [16,17]. Salinity and total dissolved solids are based on electrolytic conductivity measurements; however, we chose to report these three parameters at the reader's convenience.…”
Section: Data Collectionmentioning
confidence: 99%
“…High chloride content is dangerous to human life; therefore, it is important to carefully monitor the chloride content in water. There is a need to develop new methodologies that are characterized by high sensitivity, high throughput and high anti-interference ability [25]. Our system offers ultra-high sensitivity for chloride anions, with a detection limit of 0.5 fM.…”
Section: Introductionmentioning
confidence: 99%