Review of low-GWP refrigerant pool boiling heat transfer on enhanced surfaces

Abstract: Global warming mitigation efforts have stimulated investigations of a new generation of low-GWP refrigerants. Because some of the proposed low-GWP refrigerants have unfavorable characteristics (e.g., flammability and toxicity), a small refrigerant charge is desirable. Compact heat exchangers with enhanced surfaces facilitate small refrigerant charge by having a large heat exchanger surface area to heat exchanger volume ratio. This paper reviews the current state-of-the-art for pool boiling heat transfer of low… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
1

Year Published

2019
2019
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(8 citation statements)
references
References 102 publications
0
7
0
1
Order By: Relevance
“…A well-known method to reduce the flammability risk of HCs and extend their use is to improve their heat transfer performance in condenser and evaporator. The pool boiling heat transfer of low GWP alternatives on enhanced surfaces was reviewed by Lin and Kedzierski (2019), but neither R1150 nor R170 was included. However, their overview of the predictive methods can be useful to size compact heat exchangers with small refrigerant charge and a large heat exchange area.…”
Section: Natural Refrigerantsmentioning
confidence: 99%
“…A well-known method to reduce the flammability risk of HCs and extend their use is to improve their heat transfer performance in condenser and evaporator. The pool boiling heat transfer of low GWP alternatives on enhanced surfaces was reviewed by Lin and Kedzierski (2019), but neither R1150 nor R170 was included. However, their overview of the predictive methods can be useful to size compact heat exchangers with small refrigerant charge and a large heat exchange area.…”
Section: Natural Refrigerantsmentioning
confidence: 99%
“…El dato de emisiones históricas ha hecho que el mayor volumen de asignaciones recaiga en el sector de generación-combustión [3]. El incremento de la demanda de energía y consumo de refrigerantes como los hidrofluorocarbonos (HFC), los cuales presentan un potencial de calentamiento global (GWP) mayor a 1000, conlleva un rápido aumento de las emisiones de CO2 en la atmósfera [4]. En la Fig.…”
Section: Impacto Ambientalunclassified
“…On the other hand, the manufacturing precision is lower than the bare solid surface and its modeling is much more difficult due to the random porous structure. In addition, oil fouling inside and outside the porous body have been reported, and, for this reason, the working fluid is limited to fluids that are clean and free of impurities [15][16][17].…”
Section: Introductionmentioning
confidence: 99%