2022
DOI: 10.1016/j.measurement.2022.111794
|View full text |Cite
|
Sign up to set email alerts
|

Review of optical measurement techniques for measuring three-dimensional topography of inner-wall-shaped parts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 114 publications
0
10
0
Order By: Relevance
“…Due to the perspective-n-point (PNP) [22][23][24] principle, which is used to solve the coordinates of the light probe, at least several sets of points are required for calculation. 25 In general, the light probe is two-dimensional (i.e., planar). The abutment of PICcamera system is this mode, similar to a flag.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to the perspective-n-point (PNP) [22][23][24] principle, which is used to solve the coordinates of the light probe, at least several sets of points are required for calculation. 25 In general, the light probe is two-dimensional (i.e., planar). The abutment of PICcamera system is this mode, similar to a flag.…”
Section: Introductionmentioning
confidence: 99%
“…The abutment, which is like a light probe, can measure coordinates within overlapped field-of-views of the multicamera or multiview. Due to the perspective-n-point (PNP) 22 24 principle, which is used to solve the coordinates of the light probe, at least several sets of points are required for calculation 25 . In general, the light probe is two-dimensional (i.e., planar).…”
Section: Introductionmentioning
confidence: 99%
“…6,15 White-light interferometry and confocal laser scanning microscopy (CLSM) are typical noncontact optical methods for 3D reconstruction of the surface morphology. 22 These white-light and laser-facilitated 3D microscopies have great potential to perform highthroughput screening of Li electrodes with a noncontact mode. Besides characterization tools, the nucleation behavior of metal pitting is challenging to study due to its stochastic behavior.…”
Section: ■ Introductionmentioning
confidence: 99%
“…However, 3D reconstruction methods with ion milling/sputtering are intrinsically destructive and time-consuming to remove layers of sample . Sanchez et al used operando OM to study the morphology evolution of the pit and found anisotropic pit expansion in both the in-plane and through-plane directions. , White-light interferometry and confocal laser scanning microscopy (CLSM) are typical noncontact optical methods for 3D reconstruction of the surface morphology . These white-light and laser-facilitated 3D microscopies have great potential to perform high-throughput screening of Li electrodes with a noncontact mode.…”
Section: Introductionmentioning
confidence: 99%
“…When measuring the large scene or the inner surface of annular workpieces, a rotating mechanism is commonly employed to splice the captured series of data. [7][8][9][10] However, ensuring precise alignment between the camera's optical center and the rotation axis during mounting proves challenging, thus necessitating calibration to establish the positional correlation between the camera and the rotation axis. [11][12][13] Scholars have dedicated significant efforts to the exploration of calibration techniques for rotary scanning system rotation axis.…”
Section: Introductionmentioning
confidence: 99%