Abstract:In this study, a method of water leakage detection system was investigated using acoustic emission device, AQUA M 300D. It is used to pinpoint leakage sources for underground pipelines system. The leakage is detected by analyzing the feedback frequency, where leakage area produces higher frequency due to the vibration resulting from a high-pressure liquid that flows through the crevice. The method is successful to detect underground pipelines system leakage with 90% accuracy.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.