Compared with natural wood, laminated veneer lumber has the characteristics of high strength, flexible specifications, excellent stability, and good economy. In order to study the bearing capacity of LVL trusses, the mechanical properties of LVL materials were tested. The static load test was carried out by using 3 pieces of LVL truss, and the load-deflection relationship, load-strain relationship, bearing capacity and failure mode of LVL trusses were studied. Based on the simplified joint analysis method, the metal plate connection and bolted truss were analyzed, and the bearing capacity calculation formula was developed. The results show that the upper chord instability is the main failure mode for large-span light LVL truss. A simplified formula for bearing capacity of LVL truss was proposed, and the predicted results were in good agreement with the experimental results. Finally, an application example of LVL truss engineering design and construction is briefly introduced. The research can provide technical support for the promotion and application of LVL truss of lightweight poplar wood.