2014
DOI: 10.2106/jbjs.l.01177
|View full text |Cite
|
Sign up to set email alerts
|

Revision Total Hip Arthroplasty with Retained Acetabular Component

Abstract: Adelani, Muyibat A.; Mall, Nathan A.; Nyazee, Humaa; Clohisy, John C.; Barrack, Robert L.; and Nunley, Ryan M., ,"Revision total hip arthroplasty with retained acetabular component

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0
3

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 30 publications
(57 reference statements)
1
26
0
3
Order By: Relevance
“…Periprosthetic osteolysis caused aseptic prosthetic loosening has been considered as the main factor for failure in joint replacement surgery. The limited surgical treatment choices for periprosthetic osteolysis such as complete or partial revision with bone grafting of joint replacement are far from being satisfactory because of recurrence of osteolysis (Adelani et al, 2014). The development of orthopedic material, such as highly cross-linked polyethylene (stabilized with vitamin E or not) for acetabular lining, has an uncertain effect with regard to controlling osteolysis in comparison to ultra-high-molecular-weight polyethylene (Endo et al, 2002;Boyer et al, 2018).…”
Section: Discussionmentioning
confidence: 99%
“…Periprosthetic osteolysis caused aseptic prosthetic loosening has been considered as the main factor for failure in joint replacement surgery. The limited surgical treatment choices for periprosthetic osteolysis such as complete or partial revision with bone grafting of joint replacement are far from being satisfactory because of recurrence of osteolysis (Adelani et al, 2014). The development of orthopedic material, such as highly cross-linked polyethylene (stabilized with vitamin E or not) for acetabular lining, has an uncertain effect with regard to controlling osteolysis in comparison to ultra-high-molecular-weight polyethylene (Endo et al, 2002;Boyer et al, 2018).…”
Section: Discussionmentioning
confidence: 99%
“…The risk of failure in patients who received a CUHMWPE liner at the time of the primary THA was 14.8 times higher than in patients who received an HCLPE liner because of high wear[24]. Although, fractures of HCLPE were also reported [2527].…”
Section: Discussionmentioning
confidence: 99%
“…To address the polyethylene wear associated with osteolysis, isolated liner exchange is a common surgical intervention when the acetabular component remains well fixed [1, 24]. The results showed no locking mechanism failure, no acetabular loosening, and no osteolysis.…”
Section: Discussionmentioning
confidence: 99%
“…The selected of surgical strategy according to the status of bone matrix defects requires, in extreme cases, the manu facture of a tailor-made implant [15]. Garcia and Adelai stress that a good late outcome is predominantly owed to the restoration of physiolo gical joint biomechanics [16,17]. However, taking into account the economics of the procedures, the suggestion to per form additional diagnostic testing in primary uncom pli cated hip arthrosis, as expressed by Kawasaki and Kirkpatrick, may be ex aggerated [18,19].…”
Section: Discussionmentioning
confidence: 99%
“…Se lek tyw ne do bra nie me tod ope racyj nych w za le żno ści od ubyt ków zrę bu kost ne go, w skraj nych przy pad kach wy ma ga wy ko na nia implan tu na wy miar [15]. García i Ade la ni pod kre śla ją, że do bry wy nik od le gły w du żej mie rze za le ży od odtwo rze nia pra wi dło wej bio me cha ni ki sta wu [16,17]. Uwzględ nia jąc jed nak eko no mi kę pro ce dur, au to rzy uwa żają za prze sa dę roz sze rza nie dia gno sty ki pro pono wa ną przez Ka wa sa ki czy Kirk pa trick w pier wotnych nie po wi kła nych ar tro zach bio dra [18,19].…”
Section: Dys Ku Sjaunclassified