2019
DOI: 10.1111/1462-2920.14590
|View full text |Cite
|
Sign up to set email alerts
|

Riding the wave of genomics to investigate aquatic coliphage diversity and activity

Abstract: Summary Bacteriophages infecting Escherichia coli (coliphages) have been used as a proxy for faecal matter and water quality from a variety of environments. However, the diversity of coliphages that is present in seawater remains largely unknown, with previous studies largely focusing on morphological diversity. Here, we isolated and characterized coliphages from three coastal locations in the United Kingdom and Poland. Comparative genomics and phylogenetic analysis of phage isolates facilitated the identifica… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

4
45
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 34 publications
(49 citation statements)
references
References 83 publications
4
45
0
Order By: Relevance
“…The burst size of vB_Eco_SLUR29 is 22 , which is smaller than the reported values of 194 115, 78 and 51 for vB_Eco-S59, vB_Eco_swan01 and vB_Eco_mar002J2 respectively 12,21 . There is 195 also considerable variation in the latent period for these phages, with vB_Eco_SLUR29 having a 196 substantially longer latent period (21 min) than the reported 4, 12 and 15 min for vB_Eco-S59, 197 vB_Eco_swan01 and vB_Eco_mar002J2 12,21 . However, the reported 4 min latent period of 198 vB_Eco-S59 seems extraordinarily rapid and maybe an artefact of the method used.…”
mentioning
confidence: 56%
See 4 more Smart Citations
“…The burst size of vB_Eco_SLUR29 is 22 , which is smaller than the reported values of 194 115, 78 and 51 for vB_Eco-S59, vB_Eco_swan01 and vB_Eco_mar002J2 respectively 12,21 . There is 195 also considerable variation in the latent period for these phages, with vB_Eco_SLUR29 having a 196 substantially longer latent period (21 min) than the reported 4, 12 and 15 min for vB_Eco-S59, 197 vB_Eco_swan01 and vB_Eco_mar002J2 12,21 . However, the reported 4 min latent period of 198 vB_Eco-S59 seems extraordinarily rapid and maybe an artefact of the method used.…”
mentioning
confidence: 56%
“…Mash database was constructed of all complete bacteriophage genomes available at the time of 80 analysis (~ 11,000, April 2019) using the following Mash setting: " -s 10000" using a previously 81 described method 12 . Closely related genomes were identified using this database and the `dist` 82 function.…”
Section: Bioinformatics and Comparative Genomics 73mentioning
confidence: 99%
See 3 more Smart Citations