2014
DOI: 10.3311/ppci.2113
|View full text |Cite
|
Sign up to set email alerts
|

Rising damp analysis and selection of optimal handling method in masonry construction

Abstract: Abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…On the contrary, as also mentioned in the overview and state of the art, the technologies that were the subject of this research have been applied on several sites and their effectiveness has been verified [22,35,36] The different techniques of remediation interventions in this research were chosen mainly because of the complexity of the structure and the surrounding conditions. Grouting was applied in areas where it was not possible to apply stainless-steel plate stamping and undercutting technology.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…On the contrary, as also mentioned in the overview and state of the art, the technologies that were the subject of this research have been applied on several sites and their effectiveness has been verified [22,35,36] The different techniques of remediation interventions in this research were chosen mainly because of the complexity of the structure and the surrounding conditions. Grouting was applied in areas where it was not possible to apply stainless-steel plate stamping and undercutting technology.…”
Section: Discussionmentioning
confidence: 99%
“…It is used worldwide in various types of construction. For example, a study by [22] described the use of diamond wire undercutting technology (the technology is called HIO technology) [23], which dealt with the rehabilitation of a former commercial academy building in Zrenjanin, Serbia, dating back to 1892. The detailed description of the rehabilitation of the building was divided into three steps, which were presented in detail in the paper.…”
Section: Current Status and Overview Of The Implementation Of Remedia...mentioning
confidence: 99%
“…During Experiment 2 samples were placed into a water tank to conduct long-term water absorption test with full immersion according to EN 12087:2013. As required by this standard, water absorption should be determined as a percentage by volume (V/V %) or by weight (m/w %) after 28 days of water immersion compared to air-dry condition [22]. However; the date of saturation was unknown, and it was also important to document the evolution of water absorption process in time.…”
Section: Methodsmentioning
confidence: 99%
“…The most effective method reducing the water flux is prevention through the physical separation of building materials from the ground moisture and salts by the use of a traditional damp-proof course. An impermeable barrier such as plastic, glazed brick, or bitumen is typically used [45]. However, using such protection measures in historical masonry is mostly not feasible.…”
Section: Passive Techniquesmentioning
confidence: 99%