2015
DOI: 10.1007/s40565-015-0145-8
|View full text |Cite
|
Sign up to set email alerts
|

Risk assessment framework for power control systems with PMU-based intrusion response system

Abstract: Cyber threats are serious concerns for power systems. For example, hackers may attack power control systems via interconnected enterprise networks. This paper proposes a risk assessment framework to enhance the resilience of power systems against cyber attacks. The duality element relative fuzzy evaluation method is employed to evaluate identified security vulnerabilities within cyber systems of power systems quantitatively. The attack graph is used to identify possible intrusion scenarios that exploit multipl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 10 publications
0
13
0
Order By: Relevance
“…The majority of articles found in this systematic literature review use previous research to find the different possible vulnerabilities or attacks on the systems that they model [ 4 , 13 , 16 , 19 , 23 , 26 , 28 – 30 , 34 , 46 , 52 , 53 ]. Previous research is also used in combination with other information sources [ 9 – 11 , 20 , 31 , 41 ].…”
Section: Information Sourcesmentioning
confidence: 99%
“…The majority of articles found in this systematic literature review use previous research to find the different possible vulnerabilities or attacks on the systems that they model [ 4 , 13 , 16 , 19 , 23 , 26 , 28 – 30 , 34 , 46 , 52 , 53 ]. Previous research is also used in combination with other information sources [ 9 – 11 , 20 , 31 , 41 ].…”
Section: Information Sourcesmentioning
confidence: 99%
“…Yan et al 8 Qin et al 9 Zonouz and Haghani 10 Wang et al 11 Yan and Haimes 12 Li et al 13 This study each above place has only two colors; thus, the element in (P i , c i ) in the pre-condition or postcondition represents the object has two states. Besides, the relationship among these objects can be modeled as a tree, 30 which can be divided into two types, ''AND'' and ''OR,'' as shown in Figure 9.…”
Section: Approachmentioning
confidence: 94%
“…Many researches on response strategy making have been done in the past decades. Yan et al 8 proposed a response strategy based on the phasor measurement unit (PMU) attack graph which analyzed the attack paths in smart grid. Qin et al 9 established a multimodel based on Bayesian Network for dynamic decision-making in industrial control systems (ICSs).…”
Section: Introductionmentioning
confidence: 99%
“…The traditional local control method was unable to meet the requirements of security and stability in the current wide area power system. In recent years, the wide area measurement system (WAMS) based on phasor measurement unit (PMU) has rapidly developed and widely used in power system, which promoted the development of the wide area control in power system (Hadidi & Jeyasurya, 2013;Manousakis, Korres, & Georgilakis, 2012;Yan, Govindarasu, Liu, Ming, & Vaidya, 2015). In the wide area environment, time delay exists in the process of signal transmission and processing, especially in long distance transmission.…”
Section: Introductionmentioning
confidence: 99%